Rinnai RUR98e (REU-KBP3237WD-US) Installation Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 160
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
KBP Series Manual 5

Parts included
Tools needed
Materials needed
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shuto valve during any pressure tesng of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
You must follow the installaon instrucons and
those in Care and Maintenance for adequate
combuson air intake and exhaust.

If the water heater is installed in a closed water
supply system, such as one having a backow
preventer in the cold water supply line, means
shall be provided to control thermal expansion.
Contact the water supplier or local plumbing
inspector on how to control thermal expansion.
Should overheang occur or the gas supply fail to
shut o, turn o the manual gas control valve to
the appliance.
Keep the air intake locaon free of chemicals, such
as chlorine or bleach, that produce fumes. These
fumes can damage components and reduce the life
of the appliance.
Tankless water heater with integrated pump
Color coded cold (blue) and hot (red) isolaon valves
Pressure relief valve
MC-195T temperature controller
Self Tapping Screws (Qty - 2)
Thermal By-Pass Valve
Pipe wrenches (2)
Adjustable pliers
Screwdrivers (2)
Wire cuers
Gloves
Safety glasses
Level
Tools that might be needed
Hammer drill with
concrete bits
Saw
Threading machine with
heads and oiler
Core drill with diamond
head
Torch set
Copper tubing cuer
Steel pipe cuer
Materials that may be needed
Soap or gas leak detector
soluon
Approved venng
Thermal Expansion Tank
Teon tape
(recommended) or pipe
compound
Heat tape
Pipe insulaon
Electrical wire and
conduit per local code
Concrete wall anchors
Oponal pipe cover
Oponal temperature
controller
5/8” ID PVC exible
tubing
2 conductor 22 AWG
wire for controller
Single gang electrical box
Wire nuts
Unions and drain valves
Addional Piping (for
dedicated return
applicaons)
Pressure Regulator
Check Valve
Air Separator

NOTE
The MC-195T temperature controller is
contained within the Styrofoam packing of the
tankless water heater, be sure not to discard it.
This controller is necessary for operaon with this
tankless unit.
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 159 160

Comments to this Manuals

No comments