Rinnai Australia - 10 - Solar Split Systems Operating / Installation Manual
SPECIFICATIONS FOR SYSTEMS
GENERAL
Split solar hot water systems are specified according to the grade of storage cylinder material, cylinder
capacity, number of solar collectors and boost type and capacity. Boost capacity for gas boosted
system depends on the gas booster model selected. Boost capacity for electrically boosted systems
depends on the power rating of electric heating elements and whether one or two electric heating
elements are fitted.
SYSTEM SPECIFICATIONS AND DIMENSIONS
Specifications and principal dimensions for the various systems and components are shown below.
FLOW CONTROL VALVE
A flow control valve is fitted to the pump and controller assembly.
It’s purpose is to allow the water flow rate through the collector collectors and storage cylinder to be
controlled to optimise the performance of the system.
DIFFERENTIAL TEMPERATURE CONTROLLER
The primary task of the differential temperature controller is to control the operation of the pump to
optimize solar energy collection. This task is performed by measuring the temperature differential
between the hot sensor and the cold sensor. When the differential exceeds 9°C the pump is activated
and water passes through the collectors collecting solar energy. When the differential falls below 5°C
the pump is shut down.
A secondary task of the controller is to stop energy collection when the cylinder is full of hot water.
This is referred to as no load protection and the pump is shut down if the temperature of the water
going to the collectors exceeds 65°C. At such a temperature in the base of the cylinder, the
temperature of water in the top of the cylinder is expected to be about 85°C.
Table 2 - System Specifications
System Type
Rinnai ‘Sunmaster’
Systems
SG175, SG215,
SE160, SE200
Rinnai ‘Sunmaster
Systems
SG270, SG340,
SE315
Rinnai ‘Prestige’
Systems
Connections:
Solar flow and return 1/2” 1/2” 1/2”
PTR Valve 1/2” 1/2” 3/4”
Cold Inlet 3/4” 3/4” 3/4”
Hot Outlet 3/4” 3/4” 3/4”
PTR Valve setting (kPa) 1000 850 850
Rating of PTR Valve supplied (kW) 10 10 10
Expansion Control Valve (ECV) setting
(kPa)
850 700 700
Max supply pressure with ECV (kPa) 680 550 560
Max supply pressure without ECV
(kPa)
800 680 700
Pressure limiting valve rating (kPa)
(supplied by installer if required)
500 500 500