Rinnai Q205SP User Manual

Browse online or download User Manual for Water heaters & boilers Rinnai Q205SP. Rinnai Q205SP User manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 184
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
- Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
- Do NOT try to light any appliance.
- Do NOT touch any electrical switch.
- Do NOT use any phone in your building.
- Immediately call your gas supplier from a neighbors phone.
Follow the gas suppliers instructions.
- If you cannot reach your gas supplier, call the re department.
8W.51.40.02/11.11 Changes reserved.
Installation & Servicing
Instructions
These instructions to be retained by user.
CAUTION!
Read this manual thoroughly before installing, servicing, putting
into operation or using this boiler and vent system.
WARNING!
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury
(exposure of hazardous materials)* or loss of life. Refer to the
user's information manual provided with this boiler. Installation
and service must be performed by a quali ed installer, service
agency or the gas supplier (who must read and follow the supplied
instructions before installing, servicing, or removing this boiler).
CAUTION!
The user manual is part of the documentation that is delivered
to the installation's operator. Go through the information in this
manual with the owner/operator and make sure that he or she is
familair with all necessary operating instructions.
NOTICE!
Installation and service must be performed by a quali ed
installer, service technician or the gas supplier.
Pictured: Q85SN, Q130SN
Q85SP, Q130SP
High ef ciency condensing gas boiler
Q85SN/Q130SN/Q175SN/Q205SN/Q175CN
Q85SP/Q130SP/Q175SP/Q205SP/Q175CP
WARNING!
If you do not follow these instructions exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
Address: 103 International Drive, Peachtree City, GA, 30269
Toll-free: 1-800-621-9419Fax: 678-829-1666www.rinnai.us
Français: voir page 127
Page view 0
1 2 3 4 5 6 ... 183 184

Summary of Contents

Page 1 - Instructions

- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.- WHAT TO DO IF YOU SMELL GAS-

Page 2

Installation & Servicing Instructions Rinnai Q-Series 105 Installation5.1 Requirements for the installation room- The room where the boiler

Page 3

Installation & Servicing Instructions Rinnai Q-Series 100

Page 4 - 1.3 Symbol defi nitions

Installation & Servicing Instructions Rinnai Q-Series 101- Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides infl

Page 5

Installation & Servicing Instructions Rinnai Q-Series 102Contenu des instructionsCes instructions d’installation contiennent d’importantes inform

Page 6

Installation & Servicing Instructions Rinnai Q-Series 103Contenu1 Sécurité et instructions générales ...

Page 7 - 2 Regulations and guidelines

Installation & Servicing Instructions Rinnai Q-Series 1041 Sécurité et instructions généralesVeuillez observer ces instructions dans l’intérêt d

Page 8 - 3 Description of the boiler

Installation & Servicing Instructions Rinnai Q-Series 1051.4 Les instructions suivantes doivent être suivies - La chaudière ne doit être utilis

Page 9 - 4.2 Transportation

Installation & Servicing Instructions Rinnai Q-Series 106Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au m

Page 10 - 5 Installation

Installation & Servicing Instructions Rinnai Q-Series 1071.6 Outils, matériels et équipement supplémentairePour l’installation et la maintenance

Page 11 - 5.2 Fitting the boiler

Installation & Servicing Instructions Rinnai Q-Series 1083 Description de la chaudièreLa chaudière Rinnai Q est une chaudière de chauffage centr

Page 12

Installation & Servicing Instructions Rinnai Q-Series 1094 Emballage et transport4.1 Champ d'application des livraisonsLa chaudière est li

Page 13

Installation & Servicing Instructions Rinnai Q-Series 115.2 Fitting the boiler- Remove the packaging materials. - Do not tear the packaging. T

Page 14

Installation & Servicing Instructions Rinnai Q-Series 110• Les chaudières emballées doivent toujours être soulevées et transportées par deux per

Page 15 - 5.3.1 Plumbing Kits

Installation & Servicing Instructions Rinnai Q-Series 1115.2 Raccordement de la chaudière- Retirez les matériaux d’emballage. - Ne déchirez pa

Page 16

Installation & Servicing Instructions Rinnai Q-Series 1125.3 Dimensionsdimensions Q85S, Q130S, Q175S et Q205S figure 1CEFATBQRBHJKGHJKD

Page 17 - 5.4 Technical specifi cations

Installation & Servicing Instructions Rinnai Q-Series 113dimensions tableau 1Type de chaudière CombiQ85SN/Q85SP Q175SN/Q175SPQ130SN/Q130S

Page 18 - 6 Connecting the boiler

Installation & Servicing Instructions Rinnai Q-Series 114Diamètre des raccordements tableau 2Raccordements de la chaudière / points

Page 19 - Service valve

Installation & Servicing Instructions Rinnai Q-Series 1155.3.1 Kits de plomberieRinnai équipe chaque type de chaudière d’un kit de plomberie. V

Page 20

Installation & Servicing Instructions Rinnai Q-Series 116Espaces autour minimumà combustiblesEspaces autour minimumà non-combustiblesEspaces auto

Page 21 - System cleaner

Installation & Servicing Instructions Rinnai Q-Series 1175.4 Spécifi cations techniquesSpécifications technique Tableau 4CombiQ175CN Q85SN Q130S

Page 22

Installation & Servicing Instructions Rinnai Q-Series 1186 Raccordement de la chaudièreLa chaudière est équipée des tuyaux de raccordement suiva

Page 23 - Water fi lter fi gure 10

Installation & Servicing Instructions Rinnai Q-Series 119Tuyeauterie de base de chaudière fi g. 6TPBouteille casse-pressionV1Vanne de

Page 24 - 6.1.4 Low water cut off

Installation & Servicing Instructions Rinnai Q-Series 125.3 Dimensionsdimensions Q85S, Q130S, Q175S and Q205S figure 1CEFATBQRBHJKGHJKD

Page 25 - 6.2 Expansion tank

Installation & Servicing Instructions Rinnai Q-Series 1206.1.1 Installation du kit de plomberieRinnai fournit des kit de plomberie spécifi ques

Page 26 - 6.4 Gas connection

Installation & Servicing Instructions Rinnai Q-Series 121Rinçage du circuit de la chaudière (non de l’échangeur de châleur de la chaudière)Lors d

Page 27 - fi gure 12b

Installation & Servicing Instructions Rinnai Q-Series 12211. Fermer la vanne principale sur le retour du circuit (V3) et ouvrir la station de pu

Page 28

Installation & Servicing Instructions Rinnai Q-Series 123Si la résistance de l’installation dépasse la valeur indiquée, la pompe va tour-ner à pl

Page 29

Installation & Servicing Instructions Rinnai Q-Series 124REMARQUEiREMARQUEi6.1.2 Kit de plomberie á côtéUn kit de plomberie á côté pour la coll

Page 30 - 6.6 Condensate drain pipe

Installation & Servicing Instructions Rinnai Q-Series 1256.2 Vase d’expansionUn vase d’expansion doit faire partie du système de chauffage cent

Page 31

Installation & Servicing Instructions Rinnai Q-Series 1266.4 Raccordement au gazNe travaillez sur les conduites de gaz que si vous êtes agréé

Page 32

Installation & Servicing Instructions Rinnai Q-Series 1276.4.2 Raccordement au gaz propaneLe raccordement au gaz naturel doit être conforme à l

Page 33

Installation & Servicing Instructions Rinnai Q-Series 1286.5 Alimentation en eau chaude (Chaudière combi Q175CN/Q175CP)Le raccordement de l’in

Page 34

Installation & Servicing Instructions Rinnai Q-Series 1296.5.1 Qualité de l'eau sanitairLes étapes appropriées doivent être suivies pour

Page 35 - 6.7.3.2 Placing air fi lter

Installation & Servicing Instructions Rinnai Q-Series 13dimensions table 1Boiler type CombiQ85SN/Q85SP Q175SN/Q175SPQ130SN/Q130SP Q205SN/

Page 36

Installation & Servicing Instructions Rinnai Q-Series 1306.5.4 Vanne de décharge de pression pour chaudières mixtes- Une vanne de décharge est

Page 37

Installation & Servicing Instructions Rinnai Q-Series 1316.6 Tuyau de purge du condensatCette chaudière produit de l’eau de condensation. Le con

Page 38

Installation & Servicing Instructions Rinnai Q-Series 1326.7.1 Directives d’admission / évacuationReportez-vous aux instructions particulières

Page 39

Installation & Servicing Instructions Rinnai Q-Series 133Termination court avec terminale de toit figure 15ATermination avec terminale de mur et

Page 40

Installation & Servicing Instructions Rinnai Q-Series 1346.7.2 b Exemples de systèmes parallelExemples combustions ferméesÉpaisseur de mur pour

Page 41

Installation & Servicing Instructions Rinnai Q-Series 1356.7.3 Installation du système d’aérationConsultez les codes locaux et de l’état relati

Page 42 - 200,000 BTU Boiler

Installation & Servicing Instructions Rinnai Q-Series 1366.7.3.1 Conversion la chaudière á parallel A. 1. Pousez les 2 clips un peut à l'e

Page 43 - INLET AIR DUCT

Installation & Servicing Instructions Rinnai Q-Series 137Observez 12” (30,5cm) d’espace au dessus du plus haut niveau de neige prévu ou du plus g

Page 44

Installation & Servicing Instructions Rinnai Q-Series 138Consulter le manuel Applications de la chaudière pour des informations de ventilation su

Page 45 - # way valve conversion kit

Installation & Servicing Instructions Rinnai Q-Series 1396.7.5 Installation vent direct en placard ou en alcôvePour une installation en placard

Page 46 - 8 Electrical connections

Installation & Servicing Instructions Rinnai Q-Series 14connection diameters table 2boiler connections figure 3Connection for c

Page 47 - Rinnai only

Installation & Servicing Instructions Rinnai Q-Series 1406.7.6 Dimensionnement du conduit d’évacuation et de prise d’air La chaudière à montag

Page 48

Installation & Servicing Instructions Rinnai Q-Series 1416.7.7 Longueurs des tuyaux d’air de combustion et de ventilationVous trouverez dans le

Page 49

Installation & Servicing Instructions Rinnai Q-Series 1426.7.8 Calcul du facteur de compensationLe facteur de compensation élimine ou réduit l’e

Page 50 - 9 Boiler controls

Installation & Servicing Instructions Rinnai Q-Series 1436.7.9 Système d’air ambiant (air de combustion intérieur)Avec de l’air ambiant, Rinnai

Page 51 - - function;

Installation & Servicing Instructions Rinnai Q-Series 14412in./300mm MAX12in./300mm MAXPERMANENTOUVERTURESCHAUDIÈRE10"(250mm)12"(300mm)

Page 52

Installation & Servicing Instructions Rinnai Q-Series 145Utilisation d’air intérieur pour la combustionLorsque l’on utilise l’air d’une ou plusie

Page 53

Installation & Servicing Instructions Rinnai Q-Series 1467 Réservoirs d’eau chaude sanitair extérieursNotez les exigences des codes locaux pour

Page 54

Installation & Servicing Instructions Rinnai Q-Series 147 8 Connexions électriquesLes branchements électriques à la chaudière doivent être effec

Page 55 - TO TURN OFF GAS TO APPLIANCE

Installation & Servicing Instructions Rinnai Q-Series 148Borne de connexion Q-SeriesBorne de connexion fi gure 2

Page 56 - 11 Adjustments

Installation & Servicing Instructions Rinnai Q-Series 149Schéma électrique figure 28Marquez tous les fi ls avant le débranchage en

Page 57 - Info Mode

Installation & Servicing Instructions Rinnai Q-Series 155.3.1 Plumbing KitsRinnai boilers are supplied with a Plumbing kit from factory. Find

Page 58

Installation & Servicing Instructions Rinnai Q-Series 150Schéma électrique en échelle figure 28a

Page 59 - 12 Isolating the boiler

Installation & Servicing Instructions Rinnai Q-Series 1519 Contrôles de la chaudièreLa chaudière est équipée d'un contrôle à microprocesseu

Page 60 - 13 Commissioning

Installation & Servicing Instructions Rinnai Q-Series 1529.1 Explication des boutons de fonctionsLorsque la pompe est allumée en continu, cela p

Page 61 - 13.1 Testing for gas leaks

Installation & Servicing Instructions Rinnai Q-Series 15310 Démarrage : Remplissage et désaération de la chaudière et de l’installationATTENTIONR

Page 62 - 13.3 Checking the O

Installation & Servicing Instructions Rinnai Q-Series 154Vérifi ez la valeur du pH à l’aide d’un mètre correctement ou en faisant analyser l’eau p

Page 63 - Ionization test fi gure 33

Installation & Servicing Instructions Rinnai Q-Series 155REMARQUEiLa pression de l’eau est trop faible (< 12 PSI / 0.8 bar), l’indication FILL

Page 64 - 14 Maintenance

Installation & Servicing Instructions Rinnai Q-Series 156POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHEAVERTISSEMENT: Quiconque ne respecte

Page 65 - Opening air box fi gure 37

Installation & Servicing Instructions Rinnai Q-Series 157REMARQUEi11 RéglagesQuand la chaudière est installée, le logiciel a déjà été préprogramm

Page 66 - 14.3 Maintenance activities

Installation & Servicing Instructions Rinnai Q-Series 158Mode ParamètrePARA USINEDESCRIPTIONPLAGE.. . .1 176°F température maximale d’alimentatio

Page 67 - Siphon figure 41

Installation & Servicing Instructions Rinnai Q-Series 159Mode Service SERVVALEURDESCRIPTIONPLAGE1 OFF Chaudière en fonctionnement avec fonction b

Page 68 - 14.4 Warranty

Installation & Servicing Instructions Rinnai Q-Series 165.3.2 Clearences from the boilerMinimum required clearances to combustiblesMinimum requ

Page 69 - 15 Parts of the boiler

Installation & Servicing Instructions Rinnai Q-Series 16011.2 Activation des réglages d’usine (fonction bouton vert) Pour réactiver les réglages

Page 70 - 16 Blocks and Errors

Installation & Servicing Instructions Rinnai Q-Series 16113 Mise en serviceLe travail sur la chaudière doit être effectué par une personne compé

Page 71 - 16.2 Blocks

Installation & Servicing Instructions Rinnai Q-Series 16213.1 Recherche des fuites de gazAvant de démarrer la chaudière, vous devez vérifi er le s

Page 72 - 16.3 Errors

Installation & Servicing Instructions Rinnai Q-Series 163Ne touchez pas l’intérieur du câble d’allumage lorsqu’il est débranché pendant le démarr

Page 73

Installation & Servicing Instructions Rinnai Q-Series 164- Ajustez si nécessaire la vis de réglage pour corriger la valeur de l’O2 (voir fi g. 3

Page 74

Installation & Servicing Instructions Rinnai Q-Series 165- Appuyez sur le bouton – jusqu’à ce que OFF s’affi che (maintenez le bouton enfoncé).-

Page 75

Installation & Servicing Instructions Rinnai Q-Series 166OPEN- Isolez la chaudière du système à l’aide des vannes d’isolation du kit de plomberi

Page 76 - 16.4 Other Errors

Installation & Servicing Instructions Rinnai Q-Series 167remplacement devraient être réduits ou augmentée. En cas de doute, contac-ter Rinnai.14.

Page 77

Installation & Servicing Instructions Rinnai Q-Series 168!DANGERSi la chaudière est activée avec les tiges de fi xation dans la mauvaise position,

Page 78

Installation & Servicing Instructions Rinnai Q-Series 169!AVERTISSEMENTendommagée et provoquer de graves dégâts matériels, des blessures corporel

Page 79

Installation & Servicing Instructions Rinnai Q-Series 175.4 Technical specifi cationsTechnical specifications Table 4CombiQ175CN Q85SN Q130SN Q1

Page 80

Installation & Servicing Instructions Rinnai Q-Series 1701 échangeur thermique 2 dispositif d’allumage3 ventilateur4 amortisseur d’entrée d’air5

Page 81

Installation & Servicing Instructions Rinnai Q-Series 171

Page 82

Installation & Servicing Instructions Rinnai Q-Series 17216 Blocages et erreurs16.1 Indications d’erreurs (références courtes)Une erreur détecté

Page 83

Installation & Servicing Instructions Rinnai Q-Series 173Les pages suivantes décrivent plus en détail les instructions de suivi pour résoudre les

Page 84 - 108a 109106

Installation & Servicing Instructions Rinnai Q-Series 17416.3 ErreursCode Description SolutionFormation incorrecte de la fl amme. La chaudière n’a

Page 85

Installation & Servicing Instructions Rinnai Q-Series 175Code Description SolutionErreur de l’appareil de contrôle L'humidité sur le circuit

Page 86

Installation & Servicing Instructions Rinnai Q-Series 176Code Description SolutionSignal de température maxi-male de retour d’eau dépassée (T2&g

Page 87

Installation & Servicing Instructions Rinnai Q-Series 177Code Description SolutionContact du capteur d’alimentation T1 ouvertVérifi ez les données

Page 88 - Control Tower

Installation & Servicing Instructions Rinnai Q-Series 178Complaint Description SolutionChauffage central mais pas d’eau chaude1. La touche -du pr

Page 89

Installation & Servicing Instructions Rinnai Q-Series 179Complaint Description Solution2. Vanne de réduction du débit. Vérifi ez le type de vanne

Page 90

Installation & Servicing Instructions Rinnai Q-Series 186 Connecting the boilerThe boiler has the following connection pipes;- The central heat

Page 91

Installation & Servicing Instructions Rinnai Q-Series 18018 Liste des pièces du système de ventilation18 Liste des pièces du système de ventila

Page 92 - 205a205a

Installation & Servicing Instructions Rinnai Q-Series 18119 Directives de ventilation communeNe raccordez pas une ventilation commune au tuyau d

Page 93

Installation & Servicing Instructions Rinnai Q-Series 182R 25 °C 12 k: R 100 ° C 950 : B25/85 K 0573 K/% 2,4- tneiciffeoc erutarepmeT Temp [°C]

Page 94

Installation & Servicing Instructions Rinnai Q-Series 183Annexe B - Tableau de resistance des sondes NTCTableau de resistance des sondes NTCNTC 1

Page 95

This renewed publication cancels all previous installation instructions. The company reserves the right to change the specifi cations and dimensions wi

Page 96 - 18 Parts list vent system

Installation & Servicing Instructions Rinnai Q-Series 19Boiler basic piping fi gure 7TPLow Loss HeaderV1Service valveV2 Service valve12

Page 97 - 20 Common venting guidelines

Installation & Servicing Instructions Rinnai Q-Series 2Contents of instructionsThese installation instructions contain important information for

Page 98

Installation & Servicing Instructions Rinnai Q-Series 206.1.1 Plumbing Kit installationRinnai supplies specifi c Plumbing Kits with each boiler

Page 99 - Resistance table NTC-Sensors

Installation & Servicing Instructions Rinnai Q-Series 21- Boiler system fl ushing (Not Boiler heat exchanger)When replacing an existing boiler the

Page 100

Installation & Servicing Instructions Rinnai Q-Series 2213. If the installation is a zone system be sure to purge out each zone individually14. C

Page 101 - Installation & Entretien

Installation & Servicing Instructions Rinnai Q-Series 23If the installation resistance is over the stated value; the pump will rotate at maximum

Page 102

Installation & Servicing Instructions Rinnai Q-Series 24NOTICEiNOTICEi6.1.2 Side mounting kit for the Low Loss headerA side mounting kit for th

Page 103

Installation & Servicing Instructions Rinnai Q-Series 256.2 Expansion tankAn expansion tank must be part of the central heating system. The ex

Page 104 - ATTENTION

Installation & Servicing Instructions Rinnai Q-Series 266.4 Gas connectionOnly work on gas lines if you are licensed for such work.If these i

Page 105 - AVERTISSEMENT

Installation & Servicing Instructions Rinnai Q-Series 276.4.2 Gas connection with propane gasThe gas supply connection must comply with local r

Page 106 - REMARQUE

Installation & Servicing Instructions Rinnai Q-Series 286.5 Hot water supply (Combi boiler Q175CN/Q175CP)Connection of the drinking water inst

Page 107 - 2 Règlements et directives

Installation & Servicing Instructions Rinnai Q-Series 296.5.3 Installing a valve kitA means to isolate the domestic indirect tank water heater

Page 108

Installation & Servicing Instructions Rinnai Q-Series 3Content1 Safety and general instructions ...

Page 109 - 4 Emballage et transport

Installation & Servicing Instructions Rinnai Q-Series 30- The relief valve should be added to the hot water outlet line according to the manufac

Page 110

Installation & Servicing Instructions Rinnai Q-Series 316.7 Vent system and air supply systemProvisions for combustion and ventilation air must

Page 111

Installation & Servicing Instructions Rinnai Q-Series 326.7.2a Examples vent and air supply systems (concentric)Short termination with roof term

Page 112 - 5.3 Dimensions

Installation & Servicing Instructions Rinnai Q-Series 336.7.2 b Examples vent and air supply systems (parallel)Examples sealed combustionsWall t

Page 113 - Dimensions

Installation & Servicing Instructions Rinnai Q-Series 346.7.3 Installation of the vent systemConsult local and state codes pertaining to specia

Page 114

Installation & Servicing Instructions Rinnai Q-Series 35A1B23C45867910D6.7.3.1 Boiler conversion from concentric to parallel A. 1. Push the 2 c

Page 115 - 5.3.1 Kits de plomberie

Installation & Servicing Instructions Rinnai Q-Series 366.7.4 Recommended vent/air intake terminal positionTerminals should be positioned as to

Page 116

Installation & Servicing Instructions Rinnai Q-Series 37See Boiler Applications manual for additional venting information. The termination shall

Page 117 - Q-Series

Installation & Servicing Instructions Rinnai Q-Series 38Terminal positions PVC figure 17Eq

Page 118

Installation & Servicing Instructions Rinnai Q-Series 396.7.6 Dimensioning of the exhaust and air intake duct The wall mounted boiler must be

Page 119 - Vanne de service

Installation & Servicing Instructions Rinnai Q-Series 41 Safety and general instructionsPlease observe these instructions in the interest of you

Page 120

Installation & Servicing Instructions Rinnai Q-Series 406.7.7 Combustion air and vent piping lengths.In the table below you fi nd the maximum eq

Page 121 - Décapant de système

Installation & Servicing Instructions Rinnai Q-Series 41!WARNINGQ85 Q130 Q175 Q205min max0100000112000232130024631 40 1 4 6 1041 60 2 6 10 n.a.61

Page 122

Installation & Servicing Instructions Rinnai Q-Series 426.7.9 Room Air System (indoor combustion air)When using indoor air, Rinnai strongly reco

Page 123

Installation & Servicing Instructions Rinnai Q-Series 43Confi ned Space:(Small Room, Closet, Alcove, Utility Room, Etc.)A confi ned space is defi ne

Page 124

Installation & Servicing Instructions Rinnai Q-Series 44Using Indoor Air For CombustionWhen using air from other room(s) in the building, the tot

Page 125

Installation & Servicing Instructions Rinnai Q-Series 457 External domestic hot water tanksNote the local codes for requirements for connecting

Page 126 - 6.4 Raccordement au gaz

Installation & Servicing Instructions Rinnai Q-Series 46 8 Electrical connectionsThe electrical connections to the boiler must be made in accord

Page 127

Installation & Servicing Instructions Rinnai Q-Series 47Connection terminal Q-Series24 Volts maximum 100 mACAUTIONMake sure that the power consum

Page 128 - DANGER

Installation & Servicing Instructions Rinnai Q-Series 48Label all wires prior to diconnection when servicing or replacing controls. Wiring errors

Page 129

Installation & Servicing Instructions Rinnai Q-Series 49electrical ladder diagram figure 28a

Page 130

Installation & Servicing Instructions Rinnai Q-Series 51.4 The following instructions must be followed- The boiler must only be used for its de

Page 131

Installation & Servicing Instructions Rinnai Q-Series 509 Boiler controlsThe boiler is provided with a fully automatic microprocessor control, ca

Page 132

Installation & Servicing Instructions Rinnai Q-Series 519.1 Explanation of the function buttonsWhen the pump is switched on continuously it can

Page 133

Installation & Servicing Instructions Rinnai Q-Series 5210 Starting up: Filling and de-aerating the boiler and installationCAUTIONObserve the fo

Page 134

Installation & Servicing Instructions Rinnai Q-Series 53Freeze protectionFreeze protection for new or existing systems must use glycol that is sp

Page 135

Installation & Servicing Instructions Rinnai Q-Series 5413 If A XX appears on the display, wait for 17 minutes;14 Check the water pressure and

Page 136 - fi gure 18

Installation & Servicing Instructions Rinnai Q-Series 55 FOR YOUR SAFETY READ BEFORE OPERATINGWARNING: If you do not follow these instructions e

Page 137

Installation & Servicing Instructions Rinnai Q-Series 56STEP 1STEP 2STEP 3STEP 4STEP 5STEP 6STEP 7STEP 8NOTICEiNOTICEi11 AdjustmentsWhen the boil

Page 138

Installation & Servicing Instructions Rinnai Q-Series 57Parameter ModePARA FACTORYDESCRIPTIONRANGE.. . .1 176°F maximum supply temperature CH 68

Page 139

Installation & Servicing Instructions Rinnai Q-Series 58Service ModeSERVVALUEDESCRIPTIONRANGE1 OFF boiler in operation with burner function on OF

Page 140

Installation & Servicing Instructions Rinnai Q-Series 5911.2 Activating factory settings (green button function) To activate the factory settings

Page 141

Installation & Servicing Instructions Rinnai Q-Series 61.5 Follow these instructions for the space heating waterUnsuitable heating system water

Page 142

Installation & Servicing Instructions Rinnai Q-Series 6013 CommissioningWork on the boiler must be carried out by a competent person, using corre

Page 143 - Chaudière 200,000 BTU

Installation & Servicing Instructions Rinnai Q-Series 6113.1 Testing for gas leaksPrior to start-up of the boiler you must check the external tig

Page 144 - ENTRÉE D’AIR

Installation & Servicing Instructions Rinnai Q-Series 6213.3 Checking the O2The O2 percentage setting has to be checked at commissioning, mainte

Page 145

Installation & Servicing Instructions Rinnai Q-Series 63Ending the O2 measuring procedure:- Press the - button until is shown (keep button pres

Page 146

Installation & Servicing Instructions Rinnai Q-Series 64- Disconnect the measuring device and restore the plug and the socket connection on the

Page 147 - 8 Connexions électriques

Installation & Servicing Instructions Rinnai Q-Series 65OPENThe air box- Remove the transparant air box (fi gure 37);- Clean the box with a clo

Page 148

Installation & Servicing Instructions Rinnai Q-Series 6614.3 Maintenance activitiesThe fan unit and burner cassette (fi gure 38 to 4) (every 4 yea

Page 149

Installation & Servicing Instructions Rinnai Q-Series 67Condensate trap and condensate tray (fi gure 41-43) (2 and 4 year maintenance)Step 1: Cond

Page 150

Installation & Servicing Instructions Rinnai Q-Series 68Visual inspection of the fl ame (2 and 4 year maintenance)The burner must fl ame evenly ove

Page 151 - 9 Contrôles de la chaudière

Installation & Servicing Instructions Rinnai Q-Series 691 heat exchanger 2 ignition unit3 fan unit4 air inlet damper5 gas valve6 automatic de-ae

Page 152

Installation & Servicing Instructions Rinnai Q-Series 71.7 Relevant Installation, Service and User manuals– Approved vent system– Rinnai Boil

Page 153

Installation & Servicing Instructions Rinnai Q-Series 7016 Blocks and Errors16.1 Error indication (short reference)A detected error is indicated

Page 154

Installation & Servicing Instructions Rinnai Q-Series 71The following pages describes more detailed follow up instructions for solving blockings,

Page 155

Installation & Servicing Instructions Rinnai Q-Series 7216.3 ErrorsCode Description SolutionIncorrect fl ame formation. boiler has not been burnin

Page 156 - (Soupape principale)

Installation & Servicing Instructions Rinnai Q-Series 73Code Description SolutionControl unit error1 Anticipation resistance wire not presentWhen

Page 157

Installation & Servicing Instructions Rinnai Q-Series 74Code Description SolutionNo signal from the fan The fan is not running. Check the wiring

Page 158 - Mode Info

Installation & Servicing Instructions Rinnai Q-Series 75Code Description Solutioncontact for return sensor T2 openCheck the data in Error mode. B

Page 159 - Outdoor reset

Installation & Servicing Instructions Rinnai Q-Series 76Complaint Description SolutionCentral heating but no domestic hot water1. -Key of the DHW

Page 160

Installation & Servicing Instructions Rinnai Q-Series 77Complaint Description Solutiontemperature drop of the Solo hot water with the DHW cylinde

Page 161 - 13 Mise en service

Installation & Servicing Instructions Rinnai Q-Series 78Parts casing Q-Series / Pièces de manteau Serie Q17 Spare parts / Pièces de rechange0103

Page 162

Installation & Servicing Instructions Rinnai Q-Series 79ItemDescription DescriptionPart No.NPNPNPNPNP1CASING 25/38MANTEAU 25/38809000011 X X X X1

Page 163 - 13.3 Vérifi cation de l’O

Installation & Servicing Instructions Rinnai Q-Series 83 Description of the boilerThe Rinnai Q boiler is a room sealed, condensing and modulatin

Page 164 - High Altitude Label (example)

Installation & Servicing Instructions Rinnai Q-Series 80Parts heat exchanger Q-Series / Pièces d'échangeur de chaleur Serie Q303164323334353

Page 165

Installation & Servicing Instructions Rinnai Q-Series 81ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 166

Installation & Servicing Instructions Rinnai Q-Series 82Parts heat exchanger Q-Series / Pièces d'échangeur de chaleur Serie Q303164323334353

Page 167

Installation & Servicing Instructions Rinnai Q-Series 83ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 168

Installation & Servicing Instructions Rinnai Q-Series 84Parts rear wall Q-Series / Pièces des parts d'unité arrière Serie Q87 112 113 114 1

Page 169 - 14.4 Garantie

Installation & Servicing Instructions Rinnai Q-Series 85ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 170 - 15 Pièces de la chaudière

Installation & Servicing Instructions Rinnai Q-Series 86Parts rear wall Q-Series / Pièces des parts d'unité arrière Serie Q87 112 113 114 1

Page 171

Installation & Servicing Instructions Rinnai Q-Series 87ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 172 - 16 Blocages et erreurs

Installation & Servicing Instructions Rinnai Q-Series 88Parts electrical components Q-Series / Pièces des components d'électrique Serie Q152

Page 173 - 16.1 Blocages

Installation & Servicing Instructions Rinnai Q-Series 89ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 174 - 16.3 Erreurs

Installation & Servicing Instructions Rinnai Q-Series 94 Packaging and transportation4.1 Scope of deliveryThe boiler is supplied ready for use.

Page 175

Installation & Servicing Instructions Rinnai Q-Series 90Parts electrical components Q-Series / Pièces des components d'électrique Serie Q152

Page 176

Installation & Servicing Instructions Rinnai Q-Series 91ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 177

Installation & Servicing Instructions Rinnai Q-Series 92Parts tank (Combi boilers) Q-Series / Pièces de ballon d'ECS (combi) Serie Q205a205a

Page 178 - 16.4 Autres erreurs

Installation & Servicing Instructions Rinnai Q-Series 93ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 179

Installation & Servicing Instructions Rinnai Q-Series 94Parts plumbing kit Q-Series / Pièces kit de plomberie Serie Q301302303304305306307308300

Page 180

Installation & Servicing Instructions Rinnai Q-Series 95ItemDescription DescriptionPart No.NPNPNPNPNPQ205SOSS3 OSS1 OSS2 OSS3 OSS4Q175C Q85S Q130

Page 181

Installation & Servicing Instructions Rinnai Q-Series 9618 Parts list vent systemVent ProductsManufacturer Descriptions Parts #HeatfabDGV 3"

Page 182 - Coeffi cient de température

Installation & Servicing Instructions Rinnai Q-Series 9720 Common venting guidelinesDo not common vent with the vent pipe of any other boiler or

Page 183

Installation & Servicing Instructions Rinnai Q-Series 98R 25 °C 12 k: R 100 ° C 950 : B25/85 K 0573 K/% 2,4- tneiciffeoc erutarepmeT Temp [°C]

Page 184 - 800000021 11/2011

Installation & Servicing Instructions Rinnai Q-Series 99Resistance table NTC-SensorsTemp NTC 12K °F(12k:/77°F) supply sensor T1 return

Comments to this Manuals

No comments