System Maintenance
To protect yourself from harm, before performing maintenance:
Turn o the electrical power supply by unplugging the power cord or by turning o the electricity at the
circuit breaker. (The temperature controller does not control the electrical power.)
Turn o the gas at the manual gas valve, usually located immediately below the water heater.
Turn o the incoming water supply. This can be done at the isolaon valve immediately below the water
heater or by turning o the water supply to the building.
WARNING
Keep the appliance area clear and free from combusble materials, gasoline, and other
ammable vapors and liquids.
WARNING
The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be per-
formed by a licensed professional. The licensed professional must verify proper operaon aer servicing.
Air Screen Inspecon, Detecon & Cleaning
A. Inspecon:
To maintain opmum performance, periodically
inspect the HTT Engine Air Screen.
If the Air Screen appears to have lint and/or dust
build up, follow the cleaning procedure described
in step C.
If the air screen appears damage, contact a quali-
ed service provider for a replacement air lter
assembly (Part No. 108000030)
B. Detecon: (Controller Flashing 05 or 13)
Flashing error code 05 or 13 may be an indicaon
that the Air Screen is dirty or restricng air ow to
the water heater. Follow the cleaning procedure
described in Step C.
If the controller connues to ash 13 aer clean-
ing the Air Screen, turn o the unit and contact a
qualied service provider.
C. Cleaning:
1. Power OFF the water heater
Push the round power buon located on the
right hand side of the controller.
Display will go blank when the power is o.
2. Remove the Air Screen Door
Slide the door latch to the right
Swing the door open and pull the door o the
water heater front panel.
3. Clean the Air Screen
With mild dish soap and a so bristle brush,
scrub the screen area of the Air Screen Door.
With clean water, rinse the soap o the screen.
4. Dry the Air Screen
With a lint free towel, dry the lint screen
5. Inspect and Replace the Air Screen
Inspect the air screen for any debris that may
restrict air ow to the unit.
If the screen sll appears dirty repeat Step 3
Replace the Air Screen Door by aligning the tab
at the right of the Air Screen Door with slots on
the water heater panel. With the latch slid to the
right rotate the door to the closed posion and
lock the door in place by sliding the latch the le.
6. Power ON the water heater.
NOTE: Do not operate this water heater
if the Air Screen is not in place.