Rinnai RU98i Installation Manual

Browse online or download Installation Manual for Water heaters & boilers Rinnai RU98i. Rinnai RU98i Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1 Rinnai CVent
Common Vent Installaon Manual
For the RU98i (REU-KB3237FFUD-US) Condensing Water Heater
This manual is a supplement to the appliance manual.
Addional informaon can be obtained from the Rinnai water heater manual.
The exhaust vent system, CVent, is supplied by Ubbink.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instrucons.
If you cannot reach your gas supplier, call the re department.
Installaon and service must be performed by a licensed professional.
If the informaon in these instrucons is not followed exactly, a re or explosion
may result causing property damage, personal injury or death.
WARNING
Certified to ANS Z21.10.3 - CSA 4.3
Only for U.S. installations
This enre manual must be le for the consumer. The consumer must read and
refer to this manual for proper operaon and maintenance of the common vent system.
Page view 0
1 2 3 4 5 6 ... 33 34

Summary of Contents

Page 1 - WARNING

1 Rinnai CVent Common Vent Installaon Manual For the RU98i (REU-KB3237FFUD-US) Condensing Water Heater This manual is a supplement to the applian

Page 2 - Table of Contents

10 Rinnai CVent Part Number: 790008 CVent Back-2-Back Kit (QTY. 4) Part Number:790020 / 790021 CVent Extension (Qty. 5) Part Number:790037 Combus

Page 3 - 3 Rinnai CVent

11 Rinnai CVent Included With Kit No. Part No. Description Image Exhaust Vent Components 790005 790042 CVent Endpiece 790005 790048 Condensate

Page 4 - High Altude Installaons

Rinnai CVent 12 Venng Guidelines DO NOT  Do not install in separate distribuon systems. All water heaters common vented mus

Page 5 - CVent InLine Kit

13 Rinnai CVent Vercal Terminaon Maximum Equivalent Vent Length Number of water heaters Minimum Equivalent Vent Length Maximum Equivalent Ven

Page 6 - CVent Back-2-Back Kit

Rinnai CVent 14 CVent Terminaon Clearances This appliance along with the CVent Common Vent System is cered with the Cvent 8-in Wall Terminaon

Page 7 - Termination Kits

15 Rinnai CVent Exhaust Vent Terminaon Clearances INSIDECORNER DETAILFIXEDCLOSEDOPERABLEFIXEDCLOSEDOPERABLEBBBAJBMCFBBEDLGAHKI[1] A vent sha

Page 8 - 8 INCH VENT COMPONENTS

Rinnai CVent 16 Check on whether local codes supersede these clearances.  Avoid terminaon locaons near a dryer vent.  Avoid terminaon loca

Page 9 - Sample Roof Assembly

17 Rinnai CVent Water Heater Clearances Indoor model RU98i to Combustibles inches (mm) to Non-Combustibles inches (mm) Top of Heater 6 * (15

Page 10

Rinnai CVent 18 Installaon Instrucons Exhaust Vent Installaon Procedures: • Aer ensuring the water heaters are mounted securely and spaced 20

Page 11 -

19 Rinnai CVent Opons for Combuson Air Vent: • For extended Intake pipe runs, PVC can be used between the Intake Header and Terminaon. • Use

Page 12

Rinnai CVent 2 Descripon The CVent Common Venng system provides longer vent lengths and fewer wall or roof penetraons than convenonal single-u

Page 13 - CVent Terminaon Clearances

Rinnai CVent 20 Installaon Instrucons Back to back Conguraon (2 to 8 water heaters) In Line Conguraon (2 to 8 water heaters) Refer to the Ub

Page 14

21 Rinnai CVent Installaon Instrucons Recommended Spacing of Water Heaters Spacing of the water heaters is crical for the common vent system to

Page 15 - TERMINATION

Rinnai CVent 22 Installaon Instrucons Install the Condensate Trap and Drain Pipe The CVent exhaust header collects condensate. A collector and

Page 16 - • Over public walkways; or

23 Rinnai CVent Common Header Check Valve Maintenance Visually inspect the check valve annually (or aer 4000 operaon hours) for obstrucons, pro

Page 17 - Maintenance Clearances

Rinnai CVent 24 Final Checklist □ Reference the Rinnai Water Heater Operaon and Installaon Manual for proper installaon of the Rinnai water he

Page 18

25 Rinnai CVent Appendix A Ubbink CVent Condensing Common Vent System Installation and Assembly Instructions These installation instructions sho

Page 19

26 Rinnai CVent List of Contents A1 Preface 22 A2 General and Local standards information

Page 20 - Installaon Instrucons

27 Rinnai CVent A2 General and Local standards information When installing and operating the CVent Common Vent System, the following valid standar

Page 21

28 Rinnai CVent A6 General Assembly Instructions Correct Pitch The pipes and formed parts must be installed at an angle of 3° incline towards the

Page 22

29 Rinnai CVent A7 Condensate and condensate drain • Condensate is produced in the CVent Common Vent System when appliances are operating. • Co

Page 23

3 Rinnai CVent Indicates an imminently hazardous situaon which, if not avoided, will result in death or serious injury. Indicates a potenally ha

Page 24 - Final Checklist

30 Rinnai CVent General Require-ments ,Remarks and Tools:  Conrm that the box contents match the above Parts list.  Use suitable tools, bewa

Page 25 - Common Vent System

31 Rinnai CVent A9 Final Installation Check List  All vent components are secure and fully engaged.  All seals are correctly positioned and

Page 26

32 Rinnai CVent A14 Installation and maintenance of the check valves •The Check Valves must be Installed vertically as first component over the a

Page 27

33 Rinnai CVent A18 Application Manufacturer’s Information The manufacturer’s identification information as displayed below must be filled out and

Page 28

Rinnai America Corporaon • 103 Internaonal Drive, Peachtree City, GA 30269

Page 29

4 Rinnai CVent Water Heater Installaon For informaon regarding the installaon of the RU98i (REU-KB3237FFUD-US) tankless water heater, please r

Page 30 - Assembly

5 Rinnai CVent CVent Starter Kit 790005 8-Inch For Back–2-Back or InLine Combustion Air & Exhaust 1 2 3 4 5 CVent InLine Kit 790007 8-Inch H

Page 31 - 31 Rinnai CVent

Rinnai CVent 6 CVent Back-2-Back Kit 790008 8-Inch Header Kit For Back-2-Back Combustion Air & Exhaust NO QTY DESCRIPTION 1 1 CVENT COLLE

Page 32

7 Rinnai CVent Parts / Kits CVent Common Venng Exhaust / Intake Components (PPtl, polypropylene translucent) Part No. Descripon Part No. Des

Page 33 - Mail: [email protected]

8 Rinnai CVent 8 INCH VENT COMPONENTS CVent 8-in Chase Cover #790030 CVent Pitched Roof Flashing (Including Storm Collar) #790003 CVent Flat Roof

Page 34 - 10/2013

9 Rinnai CVent CVent Extension D4xL18 #790035 D4xL39 #790028 4 INCH VENT COMPONENTS Sample Roof Assembly Field Supplied PVC Components Field Sup

Comments to this Manuals

No comments