Model 2402 800-621-941935
INSTALLER’S INSTALLATION INSTRUCTIONS
Remote Controls - Installation
securing screw
securing screw
wire hole
outline of remote
3 1/4 inches
1 1/16 inches
21/32 inch
1) Determine a suitable location for the
control.
2) Make three holes on the wall as
shown.
3) Run the cable between the control
and the Continuum 2402 or the
control and the other control.
4) Remove the face plate from the remote control, using a screw driver.
5) Connect the cable to the remote control.
6) Mount the control to the wall using the holes drilled in step 2.
Note: If the cable cannot be run in the wall cavity, the plastic knockout should be
removed from the top or bottom of the control to allow flush mounting with
the wall
7) Disconnect the power from the Continuum 2402.
8) Remove the cover of the Continuum 2402.
9) Remove the plastic cover from the PCB and electrical connections.
DO NOT ATTEMPT TO CONNECT THE REMOTE CONTROLS
WITH THE POWER ON, THERE'S 120 VOLT POTENTIAL,
NEXT TO THE REMOTE CONTROL CONNECTIONS INSIDE
THE UNIT. All service and wiring should be performed by a
certified installer.
10) Thread the cable through the access hole at the
base of the unit and connect the wires to the control
terminals on the right hand side bottom of the PCB.
11) Secure the control cable using the clamp provided.
12) Replace plastic cover over PCB and then replace the
cover of the Continuum 2402.