Rinnai Australia - 14 - Rinnai Luminaire® Outdoor Gas Fire - Operation and Installation Manual
The Rinnai Luminaire Outdoor Gas Fire must be installed as a permanent fixture in an outdoor area.
Determining and consideration of the position for the Rinnai Luminaire Gas Outdoor Fire will be
dependent on the configuration of the unit purchased. Additional considerations such as protection
from direct rain, wind and sea spray, openable windows, debris from trees as well as location to
neighbouring properties also needs to be considered, gas supply and clearances from combustibles
will influence where you can position this appliance.
Location will also be depended on the type of unit purchased and if being installed into a combustible
cavity.
General Clearances
Inbuilt Freestanding
Minimum of 2 x 200 cm
2
ventilation slots to be incorporated into the structure.
One at the top of the storage area and one at the base.
Structure Clearances Required Additional Detail
Below eaves,
balconies or other
projections (A)
1000 mm minimum
If the projection is a shade cloth or material awning
then this is deemed as a combustible material and
the recommended clearance is 1500 mm.
From the ground or
other surface (E)
Inbuilt - 100 mm minimum
Freestanding - 900 mm minimum
Ground level to bottom of fireplace.
Walls (D) 500 mm Side of unit to side wall.
Gas Meters 1000 mm
Drain of Soil Pipe 150 mm
Openable Windows
and doors
1000 mm
From an openable window, door or non mechanical
air inlet, or any other opening into a building with the
exception of sub-floor ventilation.
Mechanical Air Inlet 2000 mm For example: air conditioning unit.
Mantles (B) and (C) 500 mm / 300 mm
Minimum vertical clearance of 500 mm with a
maximum mantle depth of 300 mm. If mantle depth
is more than 300 mm you will need 1000 mm of
vertical clearance.
1 m safe distance
Fixed objects such as outdoor furniture, umbrellas and plants should be at least 1 m away
from the unit when it is in operation.
Installation specific
clearances
Additional clearances also need to be observed for specific installation applications, these
are detailed on the following pages.
Ensure clearing for
servicing
Ensure enough room is maintained for servicing, cleaning and general access to the
appliance.
Ventilation of structure
When using a 9 kg gas cylinder a minimum of 2 x 200 cm
2
ventilation slots must be used
(1 x top and 1 x bottom = 400 cm
2
total) to ensure safe ventilation of all structures housing
cylinders.
Mantel
A
B
C
D
Roof or Overhang
Additional structure or sidewall
E - min. 100mm
300mm
1m
1m
1m
E = 900mm Min.
600mm
Max.
1280mm Max.
100mm
300mm
100mm
APPLIANCE LOCATION