THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN)
FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED.
REFER TO INSTALLATION INSTRUCTIONS ON PAGE 6.
INSTALLER:Leave this manual with the appliance.
CONSUMER:Retain this manual for future reference.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE
IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
HOME OWNER / INSTALLER
FOR YOUR SAFETY
THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
RCE-592ACPA
VENT-FREE GAS CONVECTION HEATER
With Plasmacluster
TM
+HEPA AIR CLEANING TECHNOLOGY
FC-420 HEP
A
+
Owner's Operation and lnstallation Manual
CORPORATION
NAGOYA, JAPAN
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - RCE-592ACPA

THIS IS AN UNVENTED GAS-FIRED HEATER. IT USES AIR (OXYGEN)FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FORADEQUATE COMBUSTION

Page 2

5. Any compound used on the threaded joint of gas piping shall be a type which resists the action ofliquefied petroleum gas.6. Supplied gas pressu

Page 3 - SAFETY DEVICES

A. This appliance does not have a pilot. It is equippedwith an ignition device which automatically lights theburner. Do not try to light the burne

Page 4 - IMPORTANT POINTS

- 10 -CONTROL PANEL OPERATING INFORMATIONINSTALLATIONCheck room size and ventilation. Do notoversize. Improper sizing may cause nuisancelock outs.CONT

Page 5 - SAFETY POINTS

1. To remove the HEPA filter· Remove the screw using Philips head.· Remove the Filter Screen and the HEPA Filter.2. To install the HEPA filter·

Page 6

 TURNING ONPress the ON/OFF button to operate the heater. The ONindicator will glow green. After approximately 20 secondsthe spark generator will

Page 7

Press the Economy button to startthe Economy function.The Economyindicator will glow.Press the Economy button once moreto switch off the function.g

Page 8 - INSTALLATION INSTRUCTIONS

 OFF TIMER OPERATIONThis feature is useful on cold nights when the unit continues to operate after you have gone tobed.The OFF Timer can be selecte

Page 9 - 30''

WARNING· Ensure there are no obstacles or foreign materials directly in front of the appliance where thewarm air will discharge into the room.· En

Page 10

 Air purifier with Plasmacluster Ion Operation 1 Press Air Purifier with Ion button.· When "H" is selected, the unit willcontinually

Page 11 - MANUAL VALVE

MAINTENANCE SUGGESTIONSThis heater has been designed and constructed for a long performance life when installed andoperated properly under normal cond

Page 12

WARNINGTHIS APPLIANCE IS INTENDED FOR SUPPLEMENTAL HEATING. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVlCE OR MAINTENANCE CAN CAUSE P

Page 13 - REPLACING THE HEPA FILTER

5. Install the HEPA Filter in the HEPA Filter Screen· Install the HEPA Filter as illustrated beside.An arrow indicates position of filter installa

Page 14 - OPERATING THE HEATER

Clean air filter at least once a week. Do not wait for filter warninglamp to come on before cleaning filter. Do not use the heater withthe filter wa

Page 15

Please note: General cleaning, maintenance and wear and tear are not necessarily covered under theguarantee. CaIIs of this nature may be chargeable.-

Page 16 - TIMER OPERATION

- 21 -CAUTlON: Label all wires prior to disconnecting when servicing controls. Wire errors cancause improper and dangerous operation. Verify proper

Page 17

- 22 -

Page 18

- 23 -

Page 20

- 25 -

Page 22 - TROUBLE SHOOTING CHART

- 27 -No.001 FRONT PANEL RC-592-20-1 1 002 LOUVER ASS’Y RC-592-25-1 1 003 REAR PANEL RC-592-21-2 1 004 TC CHECK HOLDER RC-334-73-1 1 005

Page 23

- 1 -SPECIFICATIONS Overheat SwitchWhen the heater gets too hot during operation (for example when the filters or air outlet louvers are blocked) t

Page 24

In all cases, you may be able to clear the Error Message simply by turning the heater OFF, then ON again. If the Error Message still remains or return

Page 25

- 29 -

Page 26

Rinnai America Corporation warrants the products described in this warranty including any parts and components thereof, to be free

Page 27

UNPACK HEATER:Check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater is damaged, contact yoursupplier for advice. Before installing a heater, ch

Page 28

- 3 -SAFETY POINTSDo not install this heater in areas wherespray painting or plating is taking place, orin places such as hair dressers, wherethere ma

Page 29

- 4 -SAFETY POINTSDo not unplug during operationDo not allow children to put articles in thelouvers.Supervise children playing near this heater.Do not

Page 30 - ERROR MESSAGES

1. Read these rules and the instructions carefully. Check all local codes. Failure to follow these couldcause a malfunction of the heater resultin

Page 31

NOTICE BEFORE INSTALLATIONThe heater must be installed by a qualified service person according to these installation instructions.When used without ad

Page 32 - RINNAI SPACE HEATERS

Unusually tight construction is defined as construction where:a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapor