Rinnai Australia 16 Operation & Installation Manual
TROUBLE SHOOTING
TROUBLE SHOOTING CHECKLIST
Use the following chart to help determine whether a service call is required, however if you are unsure
about the way your heater is operating, contact Rinnai or your local agent.
ABNORMAL FLAME PATTERN
Each Rinnai Flame Fire heater has a distinct flame pattern. The flame should look the same every
time you start your heater, after an initial warm up period of approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your heater, such as blocked
gas injectors or artificial logs/burn media may have shifted from when the heater was first installed.
There are some warning signs that could indicate a problem. If any of the signs below occur, please
contact Rinnai.
Signs of abnormal flame performance:
Continuous unusual smell from the appliance.
Continued difficulty or delay in establishing a flame.
Flame appears either very short or very long.
Flame only burns part way across the burner.
Severe soot building up on the inside of the glass door.
Appliance turns ‘OFF’ soon after start up and does not relight.
Flame appears overly orange-yellow.
Fault
Condition
Probable
Cause
Burners fail to ignite
Smell of gas
Fan Not Working
Minor soot deposits
Severe sooting
Glass, Condensating
Glass, Streaky lines
Remote not working
Fault
Condition
Simplest Possible
Remedy
Not plugged in or turned off Plug in power cord and turn power ‘ON’.
Mains power failure Re-ignition, when power restored.
(Initial Install) Air in gas pipe Installer to purge air from gas supply.
Air in hose Repeat Ignition procedure.
Ignition failure Repeat Ignition procedure.
Flat battery for remote control Replace remote control battery.
Gas supply turned off Turn gas supply on at the meter or cylinder.
Gas escape Isolate gas supply, call Rinnai.
Inadequate flue system Call Rinnai.
Insufficient gas pressure Call Rinnai.
Log Misalignment Call Rinnai.
Normal operation No action is required.
Normal operation
Fan not working - fan automatically comes
on after 4 minutes not heat switch activated.
Normal operation Allow heater to warm up.
Heat switch not activated Allow heater to run on high for 4 minutes.
Possible fan fault Call Rinnai.
Controller display blank Replace batteries.
Manual Switch Mode select Refer to page 14 for solution.
Normal Abnormal