Rinnai Symmetry RDV3611 Installation Guide Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14 | RDV3611 Installation Manual: 11156-A 01-12
RDV3611 ue components
165
165
Flue elbow 90 °
Code = R3643
Used to facilitate vertical and
horizontal flueing. Elbow
swivels 360 ° at base. Angle not
adjustable.
Once joined effective length
reduces 35 mm.
• 90 ° = 130 mm
108
108
Flue elbow 45 °
Code = R3642
Offsets obstructions. Elbow
swivels 360 ° at base. Angle
not adjustable. Kit contains two
45 ° bends.
Once joined effective length
reduces 35 mm.
• 45 ° = 73 mm
Flue pipes
Codes
150 mm = R3630
230 mm = R3631
300 mm = R3632
450 mm = R3633
600 mm = R3634
900 mm = R3635
1200 mm = R3636
Pipe used to construct
horizontal and vertical flueing.
Cannot be cut to size. Once
joined nominal length reduces
approx. 35 mm.
45 degree offsets
Flue pipe (length and code) Offset (mm) Rise (mm)
None (bend to bend) N/A 124 340
150 mm R3630 203 419
230 mm R3631 257 473
300 mm R3632 311 527
450 mm R3633 417 633
600 mm R3634 524 740
900 mm R3635 737 953
1200 mm R3636 949 1165