Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-09
10
Installation Information - General
Before installation
Unpack the appliance and components and check for damage. DO NOT install any
damaged items.
Check all components have been supplied and that you have the correct gas type.
Read these instructions to get an overview of the steps required before starting the
installation. Failure to follow these instructions could cause a malfunction of the
appliance. This could result in serious injury and property damage.
Specication information
Data Plate Inside appliance - bottom panel front right hand side
Dimensions H-645 mm, W-750 mm, D-277 mm
Fan Type Tangential 2-speed, rating 28 W
Flue - Masonry Rinnai strongly recommends the use of a Rinnai Flexiliner Flue system. Failure to meet this
criteria may result in an unsafe situation. Installation without a exiliner ue is permissible
as long as the chimney is checked for soundness and ability to achieve a good draw.
Terminal 43 mm x 245 mm rear discharge (spigot)
Flue - Decorative Natural draft twin skin ue. Termination, an approved 100 mm cowl must be tted to
all installations. Decorative chimney installations require a Zero Clearance Box and Zero
Clearance Flue Kit. Flue dimensions, outer - 150 mm, inner - 100 mm.
Gas Connection ½ “ BSP male are to barrel union
Gas Type NG or LPG
Noise Level 49 dB(A)
Power Consumption High 80 W, Standby 4 W
Weight 39 kg