Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-09
1
TIMBERFLAME COMPACT
Operation and Installation Manual
(for serial numbers 0901 7042 and above)
Suitability
Domestic heating appliance, suitable for living rooms and open plan
areas.
This heater is not designed:
To be built directly into a combustible opening, for combustible
opening installations a Rinnai Zero Clearance Box and Flue Kit is
mandatory
To be installed or operated in places where painting is taking place, or
in places such as hair salons where there is a lot of dust and uff, and
where aerosols are used
Appliance must only be installed with an approved Rinnai ue system.
Appliance must be installed, commissioned and serviced by a licensed
tradesperson in accordance will all applicable local rules and regulations.
Please retain this manual for future reference.
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - TIMBERFLAME COMPACT

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-091TIMBERFLAME COMPACTOperation and Installation Manual(for serial numbers 0901 7042 and abov

Page 2 - LIMITED WARRANTY

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0910Installation Information - GeneralBefore installationUnpack the appliance and components

Page 3 - Contents

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0911Installation Information - LocationPositioning the applianceMain points governing locatio

Page 4

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0912Installation Information - FlueingGeneral ueing guidelinesEvery appliance requires a ue

Page 5 - Customer Information - Safety

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0913Installation Information - FlueingMasonry installations and exiliner ue systemsCheck di

Page 6 - Floor protection

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0914Installation Information - FlueingNew replace installations and ueingFor installations

Page 7 - Maintenance and servicing

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0915Installation Information - InstallationPreparationPosition plinth into cavity or zero cle

Page 8 - Fan operation

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0916Installation Information - InstallationGas connectionGas pipe sizing must consider the ga

Page 9 - Abnormal ame pattern

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0917Installation Information - InstallationInstalling the logsetLogset preparationRemove logs

Page 10 - Specication information

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0918Installation Information - TestingTesting procedureTurn gas supply on and plug the unit i

Page 11 - Electrical connection

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0919Installation Information - CommissioningComplete the installation and commissioning check

Page 12 - General ueing guidelines

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-092LIMITED WARRANTYPlease keep these instructions in a safe place for future reference.RECORD

Page 13 - 590 - 740 mm

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-0920Consumers: 0800 RINNAI (746 624)Installers: 0800 TO RINNAI (86 746 624)Address: 105 Pa

Page 14 - Combustible Material

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-093ContentsWARNINGImproper installation, adjustment, alteration, service or maintenance can c

Page 15 - Preparation

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-094Customer Information - IntroductionMade for New Zealand, made in New ZealandAll Rinnai am

Page 16 - ½" BSP MALE FLARE

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-095Customer Information - SafetyDo not restrict warm air discharge by placing articles in fro

Page 17 - Installing the logset

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-096Customer Information - GeneralBefore operationRead these instructions to get an overview o

Page 18 - Testing procedure

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-097Customer Information - GeneralHearthsA hearth is not necessary but can be used for decorat

Page 19 - Installer Details

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-098Customer Information - OperationIgnitionFirmly press the IGN button for 10 seconds and rel

Page 20 - Wiring Diagram

Rinnai New Zealand Compact Op/Install Manual: 10170-C 02-099Customer Information - TroubleshootingSymptom Cause SolutionBurner will not light No power