Rinnai Australia - 19 - Solar Split Systems Operating / Installation Manual - Version 9 - 21/11/12
FROST PROTECTION MODE ON SOLAR CONTROLLER
The Solar Controller has two different temperature modes. Low temperature mode and
standard operating mode. When the controller is in low temperature mode, the pump will
circulate water to the collectors when the temprature on the roof drops low enough, to prevent
freezing of the collectors.
Systems installed with E-Frost Collectors: Controller MUST be set to low temperature mode for
the warranty on the collector to be valid. Refer warranty booklet for more details.
Systems with other types of collectors can be set to standard operating mode.
The factory default is Low Temperature Mode.
Figure 11 - Frost Protection on Solar
Collector
Figure 12 - Dip Switches K1 & K2
Mode
Dip Switch K1 Dip Switch K2
Standard Operating Mode
SOM ‘ON’ CIR
Low temperature Mode
LTM ‘ON’ CIR
Power MUST be turned OFF to the Controller before opening the controller
box.
Power MUST be OFF when adjusting Dip Switches.
WARNING
INSTALLATION & MAINTENANCE - ALL SYSTEMS