Page view 6
Sequence of operation:
7
1. When the water temperature at the bottom of the tank (at the tank
thermistor) drops to a pre-determined temperature, the startup
sequence will begin.
2. The tankless engine’s combustion fan will begin turning, drawing
fresh air from the space. This will allow the flammable vapor sensor
to ensure the intake air is free of combustible vapors.
3. The pump will begin circulating water through the tank-tankless
loop.
4. The engine will fire when it detects the water flow from the pump.
5. The heated water from the engine will be deposited back into the
tank. The water will be directed toward the top of the tank close to
where hot water is being drawn into the plumbing system.
6. Initially as water is drawn from the tank into the engine, the Delta T
will be fairly large and the engine will operate in a high fire mode.
7. As the water at the bottom of the tank begins to heat, warmer
water will then begin to enter the engine — this will reduce the
Delta T allowing a higher flow rate through the engine.
8. As the water in the tank continues to warm and gets closer to the
set temperature, the tankless engine will automatically reduce its
gas input.
9. When the temperature at the bottom of the tank reaches the set
point, the pump turns off — the tankless engine will go into a
standby mode until the next start sequence.