Recovery Capacity and First Hour Delivered @ Temperature rise (°F) with Storage Tank
Rack System Configurations 60° Temperature Rise 70° Temperature Rise 80° Temperature Rise 90° Temperature Rise 100° Temperature Rise
Number of
TWH
Model**
WH Max
BTUH Input
Tank Size
(Gal.)
Recovery Pump Size
Recovery
Efficiency
Recovery
GPM
Recovery
GPH
First Hour
Delivered
(Gal.)
Recovery
GPM
Recovery
GPH
First Hour
Delivered
(Gal.)
Recovery
GPM
Recovery
GPH
First Hour
Delivered
(Gal.)
Recovery
GPM
First Hour
Delivered
(Gal.)
Recovery
GPM
Recovery
GPM
Recovery
GPH
First Hour
Delivered
(Gal.)
GPM Head (ft)
2
TRW02/
TRS02
398,000
100
12 30 95% 12.6 756
826
10.8 648
718
9.5 567
637
8.4 504
574
7.6 454
524
200 896 788 707
644 594
300 966 858 777
714 664
3
TRW03/
TRS03
597,000
100
18 30 95% 18.9 1,134
1,204
16.2 972
1,042
14.2 851
921
12.6 756
826
11.3 681
751
200 1,274 1,112 991
896 821
300 1,344 1,182 1,061
966 891
400 1,414 1,252 1,131
1,036 961
4
TRW04/
TRS04
796,000
100
24 30 95% 25.2 1,512
1,582
21.6 1,296
1,366
18.9 1,134
1,204
16.8 1,008
1,078
15.1 907
977
200 1,652 1,436 1,274
1,148 1,047
300 1,722 1,506 1,344
1,218 1,117
400 1,792 1,576 1,414
1,288 1,187
500 1,862 1,646 1,484
1,358 1,257
5
(TRW02 +
TRW03)
TRS05
995,000
200
30 30 95% 25.2 1,512
1,652
27.0 1,296
1,436
23.6 1,418
1,558
21.0 1,260
1,400
18.9 1,134
1,274
300 1,722 1,506 1,628
1,470 1,344
400 1,792 1,576 1,698
1,540 1,414
500 1,862 1,646 1,768
1,610 1,484
6 TRS06 1,194,000
200
36 30 95% 37.8 2,269
2,409
32.4 1,945
2,085
28.4 1,701
1,841
25.2 1,512
1,652
22.7 1,361
1,501
300 2,479 2,155 1,911
1,722 1,571
400 2,549 2,225 1,981
1,792 1,641
500 2,619 2,295 2,051
1,862 1,711
7 ** 1,393,000
300
42 30 95% 44.1 2,647
2,857
37.8 2,269
2,479
33.1 1,985
2,195
29.4 1,764
1,974
26.5 1,588
1,798
400 2,927 2,549 2,265
2,044 1,868
500 2,997 2,619 2,335
2,114 1,938
8 ** 1,592,000
300
48 30 95% 50.4 3,025
3,235
43.2 2,593
2,803
37.8 2,269
2,479
33.6 2,017
2,227
30.2 1,815
2,025
400 3,305 2,873 2,549
2,297 2,095
500 3,375 2,943 2,619
2,367 2,165
9 ** 1,791,000
300
54 30 95% 56.7 3,403
3,613
48.6 2,917
3,127
42.5 2,552
2,762
37.8 2,269
2,479
34.0 2,042
2,252
400 3,683 3,197 2,832
2,549 2,322
500 3,753 3,267 2,902
2,619 2,392
10 ** 1,990,000
400
60 30 95% 63.0 3,781
4,061
54.0 3,241
3,521
47.3 2,836
3,116
42.0 2,521
2,801
37.8 2,269
2,549
500 4,131 3,591 3,186
2,871 2,619
11 ** 2,189,000
400
66
30 95% 69.3 4,159
4,439
59.4 3,565
3,845
52.0 3,119
3,399
46.2 2,773
3,053
41.6 2,495
2,775
500 4,509 3,915 3,469
3,123 2,845
12 ** 2,388,000
400
72 30 95% 75.6 4,537
4,817
64.8 3,889
4,169
56.7 3,403
3,683
50.4 3,025
3,305
45.4
2,722 3,002
500 4,887 4,239 3,753
3,375 3,072
** Note: Multiple congurations available. TRS models are Free-Standing units;
TRW models are Wall-Mount units.Reference TRS Manual and Specication.
If common venting is used with the TRS, please contact Rinnai for assistance.
8.5” 7.25” 5.5”
Performance Chart
FOR TANKLESS RACK SYSTEMS UTILIZING STORAGE
Note:
This chart should be used only when the
existing or specified system is known.
Select TRS model to the left of chart.
Use existing or specified storage tank
with TRS selection. Reference chart to
left for recovery GPH performance.
To calculate “First Hour Delivered” add
70% of existing or specified tank volume
to recovery GPH.
Cross Reference for Existing or
Specified Systems
Existing System
Existing
or Specified Systems
BTUH
Storage
Tank
Size
Existing or
Specified TE
400,000
As specied
or existing
≥ 93%
600,000
As specied
or existing
≥ 93%
800,000
As specied
or existing
≥ 93%
1,000,000
As specied
or existing
≥ 93%
1,200,000
As specied
or existing
≥ 93%
1,400,000
As specied
or existing
≥ 93%
1,600,000
As specied
or existing
≥ 93%
1,800,000
As specied
or existing
≥ 93%
2,000,000
As specied
or existing
≥ 93%
2,200,000
As specied
or existing
≥ 93%
2,400,000
As specied
or existing
≥ 93%
DEFINITIONS:
Tank capacity: capacity of water in
gallons inside storage tank as stated
by manufacturer
Recovery pump: pump that will
circulate water from tank to TRS
during recovery period
Recovery flow rate: flow rate in
gpm at which volume inside tank is
being recovered
Recovery GPH: the water heater’s
ability to replenish hot water as it’s
drawn from the tank
Recovery efficiency: the ratio of
energy delivered to the water to the
energy content of the fuel consumed
by the water heater
First Hour Delivered (Gal): useable
volume of water that can be drawn in
one hour and is determined using the
following formula
First Hour Delivered (Gal) = Recovery
GPH +Tank capacity x 0.70
Temperature rise: temperature
difference in °F between the TRS
set point and the incoming water
temperature
Page view 0
1 2

Summary of Contents

Page 1 - Performance Chart

Recovery Capacity and First Hour Delivered @ Temperature rise (°F) with Storage TankRack System Configurations 60° Temperature Rise 70° Temperature Ris

Page 2 - Sizing Reference Guide

How to Select a TRS System Using TRS Performance Chart (Recovery GPH / First Hour Delivered Required):Find value closest to specified recovery GPH or fi