Rinnai V2532W Owner's Manual

Browse online or download Owner's Manual for Water heaters & boilers Rinnai V2532W. Rinnai V2532W Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
* For clearances not specified in ANSI Z223.1 / NFPA 54 or CAN/CGA-
B149, please use clearances in accordance with local installation codes
and the requirement of the gas supplier.
** 4 feet for Other than Direct-Vent Appliance.
1
10) Thread the cable through the access hole at the base of the unit and
connect the wires to the controller terminals on the right hand side
bottom of the PCB.
11) Secure the controller cable using the clamp provided.
12) Replace plastic cover over PCB and then replace the cover of the
Rinnai.
Suggested temperatures are:
Kitchen 120°F - 130°F, Shower 98°F - 110°F, Bath fill 102°F - 114°F
These temperatures are suggestions only. You may find higher or lower
temperatures more comfortable. Maintaining lower temperatures helps
save energy. To obtain water temperatures lower than 98°F, simply add
cold water.
Deluxe Controllers are an optional extra. ‘Controller’ and ‘Deluxe’
Controllers can be installed together. Controllers allow temperature
selection only. ‘Deluxe’ Controllers have temperature selection, bath fill and
clock functions.
Controllers allow the water temperature to be set from the various
locations where they are installed. The temperature selected will be
available to all outlets. Below are the combination of Controllers that are
offered by Rinnai:
Controllers Combination Pattern
**See controller manual in controller carton box for more infomation detail.
Water Smart / Bath Fill Temperature Table
2
The vent pipe has a negative slope/grade to the outside of three
degrees (3°) or 5/8" per foot of vent pipe. If the vent pipe is sloped back
towards the appliance as some code may require, provisions SHALL
be made to collect all condensation to drain off and away from the
appliance to a proper drain source. See local code for details.
You have no more than three bends in your vent system and the length
does not exceed Rinnai specifications.
The settings below are factory default settings. Please ensure the model
number and gas type of the unit you have, matches the model number
and gas type listed below; before settings any switches. If you need
assistance, contact Rinnai at (800)621-9419 before proceeding.
WARNING
In appropriate Dip Switch setting can damage the Rinnai water heater and
may void the warranty of this unit
9. Set the Infinity to ‘Forced Low’ combustion by setting No.7 dip switch of
the (SW1) set of dip switches to ‘ON’.(Fig.3).
10. Check the burner test point pressure.
11. Remove rubber access plug and adjust the regulator screw on the
modulating valve (Fig.4) as required in Table 1. Replace rubber access
plug.
12. Set the Rinnai Water Heaters to ‘Forced High’ combustion by setting
both No. 7 and No. 8 dip switches of the bottom (SW1) set to ‘ON’.
(Fig.5). Ensure maximum water flow !
13. Check the burner test point pressure.
14. Adjust the high pressure Potentiometer (POT) on the Printed Circuit
Board (PCB) as required to the pressure shown in Table 1.
IMPORTANT: Set dip switches 7 and 8 on the bottom (SW1) to ‘OFF’
to return the appliance to 'Normal' combustion. (Fig. 6).
15. Close hot water tap.
16. Turn ‘OFF’ the gas supply and 120V power supply.
17. Remove pressure gauge & replacing sealing screw.
18. Turn ‘ON’ the gas supply and 120V power supply.
19. Operate unit and check for gas leaks at test point.
20. Replace the front cover of the appliance.
3
4
Top of Heater
Back of Heater
Front of Heater
Sides of Heater
Ground
12 inches
0 inch
24 inches
6 inches
12 inches
Top of Heater
Back of Heater
Front of Heater
Sides of Heater
Bottom
2 inches
0 inch
24 inches
1/2 inches
2 inches
INSTALLER'S INSTALLATION INSTRUCTIONS
Remote Controllers- General
The remote controls for the Rinnai Water Heater allow the customer to
control the functions of the water heater and to diagnose certain fault
conditions.
Before installing the remote controllers, determine the most convenient
location(s).
When deciding on the best location for the remote controllers, please
consider the
following items:
1) Place the controllers out of reach of small children.
2) Avoid locations where the controller(s) will become hot. (over the stove,
near the oven or a radiant heater.
3) Avoid direct sunlight. (The digital monitor can be difficult to read in
direct sunlight)
4) Avoid areas where the remote can be splashed with cooking water, oil
or sauce.
5) The remote controller cables carry low voltage, 12VDC digital.
The controllers can be wired in series or in parallel depending on the
distance from the Rinnai to the controllers.
Every installation is different
CABLE
REMOTE CONTROL
REMOTE CONTROL
CABLE
CLAMP
CONNECTION TERMINALS
REMOTE CONTROLLER OPERATION
GENERAL CONTROLLER INFORMATION
DIAGNOSTIC USE OF CONTROLLER
1. To Display Maintenance Codes: Press ‘On/Off button. To sequence
through stored maintenance codes, press ‘On/Off followed by the
thermostat button.
2. To Display Water Flow through water heater: Press thermostat
button, hold for 2 seconds and simultaneously press ‘On/Off button.
3. To display Outlet Water Temperature: Press ‘thermostat button’,
hold for 2 seconds and simultaneously press ‘On/Off button.
TO CHANGE TEMPERATURES FROM °F to °C
1. Press and hold ‘On/Off button for 5 seconds while water heater is OFF.
2. To change back from °C to °F, please repeat step 1.
MUTE
To eliminate the beeping sound, press and hold and button
simultaneously until a ‘beep’ is heard (approximately 5 seconds).
Temperature controllers allows precise temperature control by the user.
When used correctly, the hot water unit will deliver the selected
temperature, even when the water flow is varied, or more than one tap is in
use. Each Temperature Controller can be individually programmed,
however the water heater unit can only deliver one set temperature at any
time. The available temperatures (°F) are as follows:
Temperature Table by Models
▲
▲
▼
▲ ▼
GAS PRESSURE SETTING AND DIAGNOSTICS
INFORMATION
NOTE: For additional installation and commissioning
information refer to Operation / Installation Manual
APPLIANCE OPERATING PRESSURES
COMMISSIONING
With all gas appliances in operation at maximum gas rate, the flowing
inlet pressure at the incoming test point on the Rinnai Water Heaters
should read 6"W.C. - 10.5"W.C. on Natural Gas and 10"W.C. - 13.5"W.C.
on Propane Gas. If the pressure is lower, the gas supply is inadequate
and the appliance unit will not operate to specification. Check gas meter,
regulator and pipework for correct operation/sizing and rectify as
required.
GAS PRESSURE SETTING
(Ensure gas pressure check under Commissioning above has been
completed first !)
The regulator is electronically controlled and factory pre-set. Under
normal circumstances it does not require adjustment during
installation. Make adjustments only if the unit is not operating
correctly and all other possible causes for incorrect operation have
been eliminated.
1. Turn ‘OFF’ the gas supply.
2. Turn ‘OFF’ 120V power supply.
3. Remove the front cover from the appliance.
4. Check gas type switches (Fig.1) are in the correct position
(dip switch 1 of SW2 ‘ON’ = NG, ‘OFF’ = LPG)
Note: ‘ON’ towards front, ‘OFF’ towards rear.
5. Attach pressure gauge to burner test point, located on the gas control.
(Fig.2).
6. Turn ‘ON’ the gas supply.
7. Turn ‘ON’ 120V power supply.
8. If remote controllers are fitted, turn the unit ‘ON’ at the kitchen controller,
select the maximum delivery temperature and open all available hot
water taps full including the shower.
(CAUTION: Ensure building occupants do not have access to hot water
outlets during this procedure).
THIS APPLIANCE MUST BE INSTALLED, SERVICED
AND REMOVED BY AN AUTHORISED PERSON
DURING PRESSURE TESTING OF THE CONSUMER PIPING
ENSURE GAS COCK SITUATED BEFORE UNIT IS SHUT-OFF.
FAILURE TO DO SO MAY RESULT IN SERIOUS
DAMAGE TO THE APPLIANCE AND POSSIBLE INJURY.
WARNING
Nat.G Prop.G Nat.G Prop.G Nat.G Prop.G
REU-V2532W
REU-V2532WC
REU-V2526W
150PSI
6"W.C.
10.5"W.C.
10"W.C.
13.5"W.C.
0.56"W.C. 0.88"W.C.
3.4"W.C. 5.1"W.C.
Table 1.
Water
Inlet Min.
Gas Inlet
Min./ Max.
Forced Low Forced High
No code or
blank
display
Nothing happens when water
flows through water heater.
Clean inlet filter screen and ensure you have at least the
minimum flow rate required to fire unit. Check for pipe dope
inside water flow control turbine.
On new installations, ensure hot and cold water lines are not
crossed.
Check for bleed over. Isolate unit from building by turning off
hot water line to building. Then open your pressure relief
valve, if unit fires, thereís a bleed over in your plumbing.
If a circulating system is in use, it must be isolated also.
Remote control does not light up but you have 12 VDC at the
terminals for controls:
Disconnect water flow control motor, then turn on hot water,
if unit fires replace water flow control assembly.
Code
Displayed
00
Fault
When checking maintenance code history,
“00” is substituted for “LC”
Build up of lime scale in heat exchanger - needs to be
flushed.
33
Heat exchanger outlet water temperature
faulty
Check H.E. outlet sensor or wiring. Measure resistance of
sensor. Clean sensor of scale build-up
52
Modulating Solenoid Valve signal abnormal
Check gas control wiring harness and measure resistance of
valve coil in ohms.
61
Combustion Fan Failure
Combustion fan or wiring harness faulty. Make sure
motor/fan turns freely. Measure resistance of motor winding.
71
SV0, SV1, SV2 or SV3
Solenoid Valve Circuit Faulty
Check all gas solenoid wiring harness and connections.
Measure resistance of each solenoid valve coil.
LC Scale build-up in Heat Exchanger
Build up of lime scale in heat exchanger ñ needs to be
flushed.
02
No burner operation during freeze
protection mode
Verify that gas supply is turned on to the water heater and
valve at meter or tank is open. Verify proper gas type and
supply pressure. Bleed air from gas line. Verify all ignition
component/wires are connected.
10
Air intake supply or exhaust blockage
Check for a restriction in exhaust or intake vent, verify proper
dip switch settings. Ensure only Rinnai approved venting
components are used.
14
Thermal Fuse
Ensure high and low fire manifold gas pressures are properly
set. Verify dip switch settings are correct. Measure
resistance in ohms of safety circuit.
11 No Ignition
Verify that gas supply is turned on to the water heater and at
meter or tank. Verify proper gas type and supply pressure.
Bleed air from gas line. Verify all ignition component/wires
are connected.
32
Outlet water temperature sensor reading
out of expected range
Check outlet temperature sensor or wiring for damage.
Measure resistance of sensor. Clean sensor of scale build -
up.
16 Over Temperature Warning
Verify dip switch settings, check manifold pressure and verify
gas type for water heater. Check for clogged heat
exchanger. Check for low water flow in a circulating system
causing short-cycling.
72 Flame Sensing Device Faulty
Check flame rod and wiring harness connections. Measure
micro amp output of sensor circuit with flame present. Clean
flame sensor of any build-up. Check for debris in burner
chamber that may block flame from sensor.
12 Flame Failure, poor ground connection
Make sure gas is turned on at the water heater; check for
obstructions in exhaust vent. Ensure only Rinnai approved
venting components are used. Verify proper grounding.
Check for debris or moisture in burner area.
Items to Inspect
INSTALLER'S INSTALLATION INSTRUCTIONS
-Warnings-
This manual must be followed exactly.
The Rinnai Water Heater is not suitable for use in pool or spa applications.
Installer must install a Pressure relief valve. Pipe pressure relief discharge to
a drain or outside environment.
Maintain proper space around the unit for proper servicing and operation.
Minimum clearances from combustible materials are listed below.
Minimum clearances from non-combustible materials are listed below.
RECOMMENDED VENT/AIR INTAKE TERMINAL POSITION
Terminals should be so positioned as to avoid products of combustion
entering openings into buildings or other flues or vents.
REF
U.S. Installations
Candadian
Installations
DESCRIPTION
K 3 feet 6 feetClearance to a forced air inlet into a building
N 2 feet 2 feetVent FIue from wall (FIat or Pitched Roof)
P 1 foot 1 footClearance between two vertical flue on the same pIane
Q 1 foot 1 footHorizontal between two terminals on the same wall
S 4 feet 4 feetClearance from terminal facing a terminal
R 5 feet 5 feet
Clearance between two Vertical flue on pitched roof above
each other
O 5 feet 5 feet
Vertical between two terminals on the same wall above each
other
M
3 feet 3 feetClearance under deck, veranda, porch, or balcony
(open on 3 sides)
L * 7 feet
Clearance above paved sidewalk or paved driveway located on
public property
J **1 foot 1 foot
Clearance to nonmechanical air supply inlet to building or the
combustion air inlet to any other appliance
INSTALLER'S INSTALLATION INSTRUCTIONS
Locating the vent terminal
REF
U.S. Installations
Canadian
Installations
DESCRIPTION
A 1 foot 1 footClearance above grade, veranda, porch, deck, or balcony
B **1 foot 1 foot
**
Clearance to window or door that may be opened
C Clearance to permanently closed window
D 3 feet 3 feetVertical clearance to ventilated soffit, eaves or overhang
E 3 feet 3 feetClearance to unventilated soffit, eaves or overhang
F 1 foot 1 footClearance to outside corner
G 2 feet 2 feetCIearance to inside corner
I * 3 feetClearance to service regulator vent outlet
H
*
3 feet within a height
15 feet. above the
meter/reguIator
assembly
Clearance to each side of center line extended above
meter/regulator assembly
INSTALLER'S INSTALLATION INSTRUCTIONS
Remote Controllers - Installation
1) Determine a suitable location for the
controller.
2) Make three holes on the wall as
shown.
3) Run the cable between the controller
and the Rinnai Water Heater or the
controller and the other controller.
4) Remove the face plate from the remote controller.
5) Connect the cable to the remote controller.
6) Mount the controller to the wall using the holes drilled in step 2.
7) Disconnect the power from the Rinnai Water Heater.
8) Remove the cover of the Rinnai Water Heater.
9) Remove the plastic cover from the PCB and electrical connections.
DO NOT ATTEMPT TO CONNECT THE REMOTE CONTROLLERS WITH
THE POWER ON, THERE'S 120 VOLT POTENTIAL, NEXT TO THE
REMOTE CONTROLLER CONNECTIONS INSIDE THE UNIT. All service
and wiring should be performed by a certified installer.
1
11
32
"
3
5
16
"
model
REU-V2526W(°F)
REU-V2532W
REU-V2532WC(°F)
Approx.
temperature(°C)
37
98
98
38
100
100
39
102
102
40
104
104
41
106
106
42
108
108
43
110
110
46
115
115
49
120
120
52
125
125
54
130
130
57
135
135
60
140
140
66
150
71
160
85
185
temperature
water smart/
bath fill temperature (°F)
Approx.
temperature (°C)
49
120
48
118
47
116
46
114
44
112
43
110
42
108
41
106
40
104
39
102
38
100
37
98
temperature
1 +
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
MC-91-1US
MC-91-1US
MC-91-1US
MC-91-1US
MC-91-1US
MC-91-1US MC-91-1US BC-100V MC-100V
MC-100V
MC-91-1US **MC-91-1US
MC-91-1US
BC-100V
MC-91-1US
MC-91-1US
MC-91-1US2
3
4
5
6
Remote and Deluxe Controllers
By-pass Flow Control: (REU-V2532W/WC ONLY)
(IG) Ignition System:
(FM) Combustion Fan Motor:
Set your meter to the hertz scale. Reading across the red and yellow wires at terminals 2 and 3
you should read between 60 and 350 hertz.
Thermal Fuse:
Overheat Switch:
Flame Rod:
Place one lead of your meter to the flame rod and the other to earth or ground. With the unit
running you should read between 5 ~ 150 VAC. Set your meter to the µ amp scale, series your
meter in line with the flame rod. You should read 1µ or greater for proper flame circuit. In the
event of low flame circuit remove the flame rod and check for carbon and/or damage.
Heat Exchanger, Air Temperature, and Outgoing Water Temperature Thermistors:
Check all thermistors by inserting meter leads into each end of the thermistor plug. Set your
meter to the 20K scale and read resistance. You should be able to apply heat to the thermistor
bulb and see the resistance decrease. Then apply some ice to the thermistor and the resistance
should increase. See below for examples of temperatures and resistance reading at those
temperatures.
Example: 59°F = 11.4 ~ 14K
86°F = 6.4 ~ 7.8K
113°F = 3.6 ~ 4.5K
140°F = 2.2 ~ 2.7K
221°F = 0.6 ~ 0.8K
Outgoing Water Thermistor:
Heat Exchanger Temperature Thermistor:
Surge Protector:
With the power off you can check the continuity through the surge protector. Place one meter
lead on the top pin #1 of the surge protector and pin #2 on the bottom of the surge protector.
Then check across top pin #3 and bottom pin #1, if you read continuity across these two points
the surge protector is good. If you do not get continuity, replace the surge protector.
Remote Controls:
Frost Protection:
This unit has four frost protection heaters mounted at different points inside the unit, to protect
the water heater from freeze ups. There are two heaters located on the outlet hot water line
next to the thermistor.
Using a voltage meter set on the 200 ohm scale, you should have a resistance reading of 26 ~
30 ohms through each of these heaters. The heater located on the heat exchanger piping
should have a resistance reading of 81 ~ 86 ohms and the one located in the water flow sensor
valve has a resistance reading of 16 ~ 19 ohms. Voltage throughout this circuit should be 120
VAC.
Amp Fuses:
This unit has two inline (3) amp glass fuses. Remove the fuse and check continuity through it. If
you have Continuity through the fuse, it is good. If you can not read continuity, the fuse is blown
and must be replaced.
SERVICEMAN'S TROUBLESHOOTING INFORMATION
for the RINNAI WATER HEATERS
IMPORTANT SAFETY NOTES:
There are a number of (live) tests that are required when fault finding this
product. Extreme care should be used at all times to avoid contact with
energized components inside the water heater. Only trained and qualified
service agencies should attempt to repair this product. Remember,
before checking for resistance readings, you should disconnect the power
source to the unit and isolate item the to be checked from the circuit (unplug it).
(TR) Transformer:
(SV1, SV2, SV3 and POV) Gas valve and Modulating solenoids: (Set meter above 2K)
(M) Water Flow Control Device Servo or Geared Motor:
NOTE: The grey wire listed above turns to black at B connector on the PCB, the orange wire turns to red.
Wire color
Black ~ White
Blue ~ Brown
Voltage
90 ~ 100 VAC
108 ~ 132 VAC
Resistance
51 ~ 63 ohms
51 ~ 63 ohms
Connector #
F9
F7
Pin #'s
1 ~ 2
1 ~ 3
Red ~ Black
White ~ Black
Yellow ~ Black
6 ~ 45 VDC
5 ~ 10 VDC
11 ~ 13 VDC
N/A
9.2K ~ 9.4K
3.5K ~ 3.9K
A1
A1
A1
1 ~ 2
2 ~ 4
2 ~ 3
(Main) Pink ~ Black
(SV1) Black ~ Yellow
(SV2) Black ~ Blue
80 ~ 100 VDC
80 ~ 100 VDC
80 ~ 100 VDC
1.7K ~ 2K ohms
1.7K ~ 2K ohms
1.7K ~ 2K ohms
E1
E2
E3
1 ~ 2
2 ~ 3
2 ~ 4
(SV3) Black ~ Brown 80 ~ 100 VDC 1.7K ~ 2K ohms E4 2 ~ 5
(POV) Pink ~ Pink 2 ~ 15 VDC 67 ~ 81 ohms C2 3 ~ 4
Grey ~ Grey 90 ~ 100 VAC N/A A1 1 ~ 2
Red ~ Red 12 VDC Below 1 ohm B ~ C B6 ~ C1
Red ~ Red 12 VDC Below 1 ohm B ~ C B6 ~ C1
White ~ White N/A See example above B B3 ~ B4
White ~ White N/A See example above B B3 ~ B12
Terminals D1 10 ~ 13 VDC digital 1.5K ~ 1.9K ohms H 1 ~ 3
Black ~ White
Blue ~ Brown
108 ~ 132 VAC
108 ~ 132 VAC
N/A
N/A
Surge Protector D1
Surge Protector D2
1 ~ 3
1 ~ 2
Brown ~ White
Orange ~ White
Yellow ~ White
Red ~ White/ Ground
2 ~ 6 VDC
Unit in operating
mode
15 ~ 35K
G4 ~ G5
G2 ~ G5
4 ~ 5
2 ~ 5
G1 ~ G5
G3 ~ G5
1 ~ 5
3 ~ 5
(QS) Water Flow Sensor:
Black ~ Red
Yellow ~ Black
11 ~ 13 VDC
4 ~ 7 VDC
5.5K ~ 6.2K
1 meg ~ 1.4 meg
B4
B4
5 ~ 6
1 ~ 5
Red ~ Blue
Grey ~ Brown
Grey ~ Yellow
11 ~ 13 VDC
4 ~ 6 VDC
N / A
22 ~ 26 ohms
N / A
N / A
B2
B2
B2
9 ~ 10
5 ~ 7
5 ~ 8
Grey ~ Orange 11 ~ 14 VDC N / A B2 5 ~ 6
REU-V2532W-US
REU-V2532WC-US
REU-V2526W-US
U245-2610(02)
In Use Indicator
Indicates that a hot water tap
is open and that control of the
temperature has been taken at
another controller.
Digital Monitor
Indicates the selected
water temperature.
Error messages flash
in the event of a failure.
Thermostat
Increases or decreases
the desired water
temperature.
Priority Indicator
Indicates whether this
controller has priority
control over the water
temperature
Priority
Pressing takes control
of the water temperature
by this controller.
ON/OFF
Used to switch the
water heater on and off
Attention Installer! - Have You Checked Everything?
For full details - Always Refer to Rinnai Installation Instructions
HOT (outlet) and COLD (inlet) water lines are not crossed to the unit
and are leak free.
You have installed isolating valves, unions, and drain down vales on the
cold water inlet line and hot water outlet lines. (These components are
used for servicing and/or removing the appliance quickly).
COLD water inlet filter was cleaned after installation. (The filter MUST
be cleaned after installing the unit)
A pressure relief valve is installed and is rated for 200,000 Btu's at 150
PSI per local code.
120 VOLTS A.C. is connected to the unit, it is properly GROUNDED
and circuit is turned on.
Gas supply system is properly sized. All gas meters, regulators, gas
line types, tanks, etc. have a BTU value. Please confirm that all
components meet the gas requirements at this location. Verify the
system is functioning correctly by connecting your manometer to the
gas pressure test port on the Rinnai unit. Operate all gas appliances in
the facility. The inlet gas pressure must not drop below that listed in the
ownerís manual specification sheet or appliance rating plate.
Proper gas type and pressure is supplied to the unit. (See owner's
manual for correct inlet gas pressures in the specification section.
Normal inlet gas pressures are 7" to 10" of water column for natural
gas, and 11" to 13" of water column for propane gas).
Gas supply pipe is purged of foreign material before connection.
Proper model controllers are used, connected and functioning.
Instructed the customer how to operate the Controllers.
Verify proper clearances around the unit and all vents and air intakes.
(See owner's manual for all clearance requirements.)
Explained to the customer to never store anything around the vent
terminals or block the air and/or exhaust ports to the unit.
For Internal models only
Ensure you used the proper venting materials for the unit you have
installed.
Rinnai Water Heaters
Dip Switch Default Settings
Fig. 3
Fig. 5 Fig. 6
ON
ON
SW1
ON
SW1
Fig. 2Fig. 1
Fig. 4
Regulator adjustment
screw access plug
Burner test point
GAS
COLD water inlet filter
inlet GAS test port
WATER INLET
(COLD)
WATER OUTLET
(HOT)
070 00012 30791 6
03
Power interruption during Water Smart/Bath Fill
(Hot water will not flow when power returns)
Turn off all hot water taps. Press ON/OFF twice.
65
Water Flow Servo Faulty
(Does not stop flow properly)
Water Flow Servo or wiring faulty. Check Water Flow Servo
wiring harness conection.
Measure resistance of Water Flow Servo wiring.
Page view 0
1 2

Summary of Contents

Page 1 - U245-2610(02)

* For clearances not specified in ANSI Z223.1 / NFPA 54 or CAN/CGA-B149, please use clearances in accordance with local installation codes and the req

Page 2 - PARTS LIST

EXPLODED VIEW - CABINETPARTS LISTPart NumberU245-1110U245-1110-2U245-1100U245-1100-2U195-121U245-120U245-107CF79-41020-ABU195-167AU115-163BU56-602-NAU