The Rinnai Ultra Series Tankless Water Heater RUR Models
SAVING TIME, WATER AND MONEY WITH SMART RECIRCULATION.
13
Recirculation in action… HOW THE RUR WORKS.
13
HOT WATER
COLD WATER
Crossover Valve
In applications where a dedicated recirculation line is not available or too costly to install, the RUR Tankless Water Heater will
also work using the crossover method of hot water recirculation. The RUR’s integrated recirculation pump, internal bypass line and
thermal bypass valve, which is included as standard with every RUR unit, make the crossover method of recirculation possible. The
valve is installed between the hot and cold supply lines on the furthest fixture in the plumbing line from the tankless water heater.
The cold water line is then used temporarily as the return portion of the circulation loop.
In the Crossover Mode, the integrated pump circulates water from the tankless water heater through the hot water supply line,
through the thermal bypass valve, and back to the tankless water heater via the cold water line. When hot water is detected at the
valve, the water flow through the thermal bypass valve reduces down to barely a trickle, continuing to sense water temperature in
the line. The pump will continue to operate and recirculate inside the water heater only until the end of the time interval and will
restart at the beginning of the next interval. Installation of the bypass filter thats included in the box is used in the Crossover Mode
to allow the internal circulation of water through the water heater after the thermal bypass valve has closed.
In Crossover mode, the RUR again provides for additional control of the integrated pump through time-only based Comfort or
Economy Mode settings. In Comfort Mode, the typical pump on/off intervals will vary depending on the length of recirculation
loop used. For a short loop, the pump will be on for 8 minutes, off for 4; long loop, on for 16 minutes off for 4. In Economy
Mode, again the typical pump on/off intervals will vary depending on the length of recirculation loop used. For a short loop, the
pump will be on for 8 minutes, off for 10; long loop, on for 16 minutes, off for 10, providing additional energy and cost savings.
Regardless of the hot water recirculation method used, the end result is the same: During active circulation periods, hot water is
always available as it circulates from the hot water line back to the Rinnai RUR tankless heater.
CROSSOVER MODE
Installed Thermal Bypass Valve