Rinnai Australia 1 Installation Manual
INSTALLATION GENERAL
TABLE OF CONTENTS
CERTIFICATION ....................................................................................... 1
GENERAL .................................................................................................. 1
FF FLUEING OPTIONS ............................................................................. 2
GENERAL INSTALLATION METHODS ................................................... 3
DIRECT HORIZONTAL FLUE ................................................................... 4
EXTENDED HORIZONTAL FLUE ............................................................. 4
VERTICAL FLUE ....................................................................................... 5
COMBINED VERTICAL & HORIZONTAL FLUE ...................................... 5
CONDENSATE DRAIN .............................................................................. 6
DIMENSIONS ............................................................................................ 8
CLEARANCES .......................................................................................... 9
CONTACT INFORMATION ..................................................................... 10
CERTIFICATION
Certified by the Australian Gas Association (AGA) For use only with Rinnai internal continuous flow water heaters.
GENERAL
1. These instructions only apply to the Rinnai FF water heater coaxial flueing system. This flue system utilises pipe
components with an aluminium inner pipe and a white plastic outer pipe.
These instructions DO NOT apply to older Rinnai water heater flueing that has either a stainless steel single skin
or stainless steel coaxial construction. If in doubt contact Rinnai.
2. Before commencing installation, please read the 'Installation Instructions - General', located inside a pouch
behind the front cover of all Rinnai water heater models. The Rinnai internal water heater range must only be
installed with Rinnai water heater flueing as referred to in these instructions.
3. The requirements of the current AS5601/AG601 and local authorities must be met, which is the installers
responsibility.
4. The required clearances of Rinnai internal continuous flow water heater when installed as a single unit are shown
in Fig.1A. The appliances are certified to be installed side by side as shown on page 7, allowing a minimum
distance between flues as follows:
• 270mm between horizontal terminals.
• 160mm between vertical cowls.
5. Rinnai internal continuous flow water heaters fitted with FF flue systems are room sealed as defined in AS5601.
No ventilation in the space where the water heater is installed is required.
6. The outer plastic section of the coaxial flue complies with temperature hazard requirements and can be installed
with zero clearance to combustible material.
This flue must be installed by an authorised person. The Installation must conform to local
regulations.
Installation must comply with the instructions supplied by Rinnai.
Service and removal must be carried out by an authorised person.