Rinnai B20 Service Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
REU-2532W Series 28 Rinnai
16. Operation Flow Principle
Check power supply
Fuses/electrical
circuit operational
combustion fan operates
Fan initial power flow abnormal
Thermo fuse melted
Solenoid valve circuit faulty
Failed to sense flame circuit
Combustionfan rpm's abnormal
90 Flashing
61 Flashing
72 Flashing
71 Flashing
52 Flashing
32 Flashing
14Flashing
Remote control
signal normal?
ON/OFF switch ON
Set Temperature displayed
Hot water tap open
water flow greater
than 0.6 gpm's
Combustion fan pre-purges
Initial check
normal?
Fan rpm check
Solenoid valve SV2 OPEN
Solenoid valve SV0 OPEN
Main gas valve SV1 OPEN
Sparker ON
Solenoid valve SV3 OPEN
Solenoid valve SV0 Closed
Solenoid valve SV1 Closed
Solenoid valve SV2 Closed
Pre-purge of combustion fan
(2 seconds)
Overheat bi metal switch faulty
Modulating solenoid valve faulty
Modulating valve Closed
Solenoid valve SV3 Closed
Sparker OFF
Eliminate cause
Disconnect power
supply
Remote control indicates no
flow OFF
ON/OFF Switch
Error display OFF
Water flow sensor stopped
Combustion fan OFF
Hot water tap closed
(after 5 seconds)
Error code displayed on remote
61 Flashing
Modulating valve Closed
Solenoid valve SV0 Closed
Solenoid valve SV1 Closed
Solenoid valve SV2 Closed
Solenoid valve SV3 Closed
D
C
(after 4 seconds)
Thermistor faulty
No
Yes
Yes
Yes
Yes
Yes
Not OK
(12.5 seconds after A)
B
No
No
No1
2
3
4
4
6
7
8
5
4
9
10
11
12
13
A
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 71 72

Comments to this Manuals

No comments