R98LSe (VA3237W)
Type of Appliance
Rinnai model number
Operation / Installation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system
REU-VA3237W
Forced combustion; outdoor only
19,000 - 237,000 BTU/h (Natural Gas or Propane)
Appliance: AC 120 Volts - 60 Hz
Controller: DC 12 Volts
Normal 99 watts
Standby 2 watts
Anti-frost protection 116 watts
Direct electronic ignition
0.6 to 7.9 GPM (50° F rise) 0.9 to 9.8 GPM (35° F rise)
98° - 140° F (98° - 185° F available with the MCC-91 controller for
commercial and hydronic applications)
120° F (factory default)
Natural or Propane (ensure unit matches gas type)
Natural Gas: 83% Propane: 83%
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control and by-pass control
15 - 150 PSI (50 PSI or above is recommended for maximum flow)
© 2008 Rinnai Corporation
R98LSe SP 5/2008
FLOW TABLE
Water Flow Capacity Curve
0
1
2
3
4
5
6
7
8
9
10
0255075100 125 150
delta T-Temperature Rise(F)
Water Flow Rate (GPM