Owner’s Operation and Installation Manual for the
EX17C (RHFE-434FTA)
EX22C (RHFE-559FTA)
Energysaver
®
Gas Direct Vent Wall Furnace
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents .......................... 2
Consumer Safety Information ....... 3
Specifications ................................ 4
Operating Instructions ................... 6
Installation Instructions ............... 15
Adjust Gas Pressure Settings ..... 28
Consumer Support ...................... 44
French Version ............................ 47
Register your product at www.rinnairegistration.com
or call 1-866-RINNAI1 (746-6241)
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Page view 0
1 2 3 4 5 6 ... 83 84

Summary of Contents

Page 1 - EX22C (RHFE-559FTA)

Owner’s Operation and Installation Manual for the EX17C (RHFE-434FTA) EX22C (RHFE-559FTA) Energysaver® Gas Direct Vent Wall Furnace INSTALLER: Le

Page 2 - Table of Contents

10 Rinnai Corporation EX17C / EX22C Manual Humidifier and Air Flow Direction Adjusting Air Flow Direction The vertical louvers may

Page 3 - Consumer Safety Information

Rinnai Corporation EX17C / EX22C Manual 11 Filters Dirty filters reduce the air flow and the appliance’s ability to produce heat. The filters s

Page 4 - Specifications

12 Rinnai Corporation EX17C / EX22C Manual Before Making a Service Call Before making a service call please check the following:

Page 5

Rinnai Corporation EX17C / EX22C Manual 13 Fault Codes If there is a malfunction the appliance may shut down as a safety p

Page 6 - Operating Instructions

14 Rinnai Corporation EX17C / EX22C Manual Troubleshooting Restart Function If there is a power failure wh

Page 7

Rinnai Corporation EX17C / EX22C Manual 15 Installation Instructions • A qualified service technician should install the appliance and inspect

Page 8

16 Rinnai Corporation EX17C / EX22C Manual Gas Connection • The gas supply line shall be gas tight, sized and so installed as

Page 9

Rinnai Corporation EX17C / EX22C Manual 17 Dimensions A full size template is provided on the cardboard packaging. DO NOT

Page 10 - CAUTION

18 Rinnai Corporation EX17C / EX22C Manual Flue Terminal Clearances XVAIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINAL IS N

Page 11

Rinnai Corporation EX17C / EX22C Manual 19 Flue Terminal Clearances 1 A vent shall not terminate directly above a sidewalk or

Page 12

2 Rinnai Corporation EX17C / EX22C Manual Consumer Safety Information Safety Definitions ... 3 Safety Be

Page 13

20 Rinnai Corporation EX17C / EX22C Manual Flue Manifold Slaesrebburerap1 1(‘A’ Flue units only)(For weatherboard installations)1Manual ValveSetOw

Page 14

Rinnai Corporation EX17C / EX22C Manual 21 Drilling Flue Hole Ensure that there are no gas or water lines, or electrical cir

Page 15 - Installation Instructions

22 Rinnai Corporation EX17C / EX22C Manual Flue Manifold Installation 1. Disassemble the flue manifold The flue consists of

Page 16

Rinnai Corporation EX17C / EX22C Manual 23 Flue Manifold Installation 5. Lock the ties Pulling hard on the left and right

Page 17

24 Rinnai Corporation EX17C / EX22C Manual Extension Kit Installation • Extension lines are through the side panel of the app

Page 18

Rinnai Corporation EX17C / EX22C Manual 25 Clearances exhaust pipe to combustibles 1 inch (25.4 mm) exhaust pipe to non-combustibles zero Ex

Page 19

26 Rinnai Corporation EX17C / EX22C Manual Extension Kit Installation Item Description FOT-201 FOT-219 FOT-220 FOT-221 FOT-1

Page 20

Rinnai Corporation EX17C / EX22C Manual 27 Pipe stopperElbowManifoldHookPipe stopper Connecting the Appliance 2. Connect the

Page 21

28 Rinnai Corporation EX17C / EX22C Manual 1. Turn off the gas and the power supply. 2. Remove the 5 screws that hold the louver assembly and fr

Page 22

Rinnai Corporation EX17C / EX22C Manual 29 6. Press the test switch twice to record the gas type code into memory. . 7. Press the ON/OFF butto

Page 23

Rinnai Corporation EX17C / EX22C Manual 3 Consumer Safety Information Safety Definitions This is the safety alert symbol.

Page 24

30 Rinnai Corporation EX17C / EX22C Manual Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you d

Page 25

Rinnai Corporation EX17C / EX22C Manual 31 Cut-Away Diagram

Page 26

32 Rinnai Corporation EX17C / EX22C Manual Wiring Diagram If any of the original wire as supplied with the appliance must be

Page 27

Rinnai Corporation EX17C / EX22C Manual 33 Ladder Diagram MARK PART NAME MS MAIN SWITCH R.TH THERMISTOR TF THERMAL FUSE F

Page 28

34 Rinnai Corporation EX17C / EX22C Manual Parts List For replacement parts call Rinnai at 1-800-621-9419.

Page 29

Rinnai Corporation EX17C / EX22C Manual 35 Parts List

Page 30 - Manual Valve

36 Rinnai Corporation EX17C / EX22C Manual Parts List

Page 31

Rinnai Corporation EX17C / EX22C Manual 37 Parts List

Page 32

38 Rinnai Corporation EX17C / EX22C Manual Parts List

Page 33

Rinnai Corporation EX17C / EX22C Manual 39 Parts List

Page 34

4 Rinnai Corporation EX17C / EX22C Manual EX17C EX22C Application For manufactured home (USA only) or mobile home or residential installation co

Page 35

40 Rinnai Corporation EX17C / EX22C Manual Parts List (Liste de pieces) No Name Nom Part Number (Numéro de la Pièce) EX22C EX22C

Page 36

Rinnai Corporation EX17C / EX22C Manual 41 Parts List (Liste de pieces) No Name Nom Part Number (Numéro de la Pièce) EX22C EX2

Page 37

42 Rinnai Corporation EX17C / EX22C Manual Parts List (Liste de pieces) No Name Nom Part Number (Numéro de la Pièce) EX22C EX22C

Page 38

Rinnai Corporation EX17C / EX22C Manual 43 No Name Nom Part Number (Numéro de la Pièce) EX22C EX22C-W (white) EX17C 710 Overheat Switch inter

Page 39

44 Rinnai Corporation EX17C / EX22C Manual Consumer Support Warranty Information Limited Warranty Gas

Page 40

Rinnai Corporation EX17C / EX22C Manual 45 Limited Warranty - continued Replacement of the product may be authorized by Rinnai

Page 41

46 Rinnai Corporation EX17C / EX22C Manual NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or lic

Page 42

Rinnai Corporation EX17C / EX22C Manual 47 Manuel d’installation et d’utilisation pour EX17C (RHFE-434FTA) EX22C (RHFE-559FTA) Energysaver® Ap

Page 43

48 Rinnai Corporation EX17C / EX22C Manual Cet appareil peut s’installer dans une maison ancienne déjà construite à emplacement fixe (aux USA uniq

Page 44 - Consumer Support

Rinnai Corporation EX17C / EX22C Manual 49 AVERTISSEMENT Comportements et pratiques de sécurité • Réparations doivent être e

Page 45

Rinnai Corporation EX17C / EX22C Manual 5 Features Natural Gas Propane Gas Minimum supply gas pressure 3.5 in (89 mm)

Page 46 - State Regulations

50 Rinnai Corporation EX17C / EX22C Manual Spécifications Rinnai poursuit constamment la mise à niveau et l’amélioration de ses produits. De ce fa

Page 47 - Energysaver

Rinnai Corporation EX17C / EX22C Manual 51 Caractéristiques • Redémarrage automatique en cas de problème d’allumage ou de combusti

Page 48 - Table des matières

52 Rinnai Corporation EX17C / EX22C Manual Connaissance du nouveau chauffage Instructions d’utilisation HUMIDIFICATEUR ÔTER LE C

Page 49 - AVERTISSEMENT

Rinnai Corporation EX17C / EX22C Manual 53 Panneau de commandes Contrôle de température Sur la base des informations collect

Page 50 - Spécifications

54 Rinnai Corporation EX17C / EX22C Manual Utilisation manuelle du chauffage Mise à l’heure 1. Appuyez sur

Page 51

Rinnai Corporation EX17C / EX22C Manual 55 Fonction de surpassement Cette fonction est utilisée uniquement quand le chauffage e

Page 52 - FILTRE À AIR

56 Rinnai Corporation EX17C / EX22C Manual Humidificateur et direction du flux d’air Le registre vertical peut être ajusté pour dirig

Page 53

Rinnai Corporation EX17C / EX22C Manual 57 Soins et entretien Filtres Des filtres sales réduisent le flux d’air et la ca

Page 54

58 Rinnai Corporation EX17C / EX22C Manual Avant d’appeler pour de l’aide Avant de lancer un appel pour recevoir de l’assistance,

Page 55

Rinnai Corporation EX17C / EX22C Manual 59 Codes de défauts En cas de dysfonctionnement, l’appareil peut se couper comme préc

Page 56 - ATTENTION

6 Rinnai Corporation EX17C / EX22C Manual Getting to Know your New Heating Appliance Operating Instructions HUMIDIFIER REMOVE BOTTOM C

Page 57

60 Rinnai Corporation EX17C / EX22C Manual Dépannage Si il y a une panne de courant, tandis que l'appliance est sur, pu

Page 58

Rinnai Corporation EX17C / EX22C Manual 61 Instructions d’installation • C’est un technicien qualifié qui doit installer cet appareil et l’insp

Page 59

62 Rinnai Corporation EX17C / EX22C Manual 2 in (50 mm) 2 in (50 mm) 40 in (1 m) Connexion de gaz • La conduite d’arrivée

Page 60

Rinnai Corporation EX17C / EX22C Manual 63 Dégagements en sortie de cheminée XVAIR SUPPLY INLET VENT TERMINAL AREA WHERE TERMINA

Page 61 - Instructions d’installation

64 Rinnai Corporation EX17C / EX22C Manual Dégagements en sortie de cheminée (Suite) Réf. Description Installations Canada Installatio

Page 62

Rinnai Corporation EX17C / EX22C Manual 65 Dimensions 29.9 in(760 mm)22.9 in(582 mm)10.1 in 257 mm 3.3 in 85 mm 6.8 in 172

Page 63

66 Rinnai Corporation EX17C / EX22C Manual Flue Manifold Slaesrebburerap1 1(‘A’ Flue units only)(For weatherboard installations)1Manual ValveSetOw

Page 64

Rinnai Corporation EX17C / EX22C Manual 67 Configuration viewed from behind the appliance. Flue Hole3 1/8"(80 mm) Perçage du trou de chemi

Page 65

68 Rinnai Corporation EX17C / EX22C Manual Installation du collecteur de fumée 1. Démontez le collecteur de fumée Il consiste en

Page 66

Rinnai Corporation EX17C / EX22C Manual 69 Installation du collecteur de fumée (Suite) 5. Blocage des attaches En tirant fort s

Page 67 - 3 1/8"

Rinnai Corporation EX17C / EX22C Manual 7 Control Panel Control Panel Sensible Temperature Contr

Page 68

70 Rinnai Corporation EX17C / EX22C Manual Lien en plas-tique Installation du kit d’extension Si nécessaire, des kits d’extensi

Page 69

Rinnai Corporation EX17C / EX22C Manual 71 Exhaust pipeExhaust pipeAir intake hoseAir intake hoseDégagements Conduite d’évacuation à matériaux c

Page 70

72 Rinnai Corporation EX17C / EX22C Manual Installation de kit d’extension Réf. Description FOT-201 FOT-219 FOT-220 FOT-221 FOT-

Page 71

Rinnai Corporation EX17C / EX22C Manual 73 Pipe stopperElbowManifoldHookPipe stopper Branchement de l’appareil 2. Branchez le

Page 72

74 Rinnai Corporation EX17C / EX22C Manual 1. Eteindre le gaz et le pouvoir fournit. 2. Retirez les 5 vis qui le couvercle Persienne assembly et

Page 73

Rinnai Corporation EX17C / EX22C Manual 75 6. Appuyer le commutateur d’essai deux fois pour entrer ce code dans la mémoire. 7. Appuyer l&apos

Page 74

76 Rinnai Corporation EX17C / EX22C Manual Instructions de mise en œuvre À LIRE AVANT DE METTRE EN MARCHE, POUR VOTRE SÉCURITÉ

Page 75 - Assemblée finale

Rinnai Corporation EX17C / EX22C Manual 77 Schéma en coupe FILTRE À AIR VENTILATEUR DE CONVECTION PANNEAU FRONTAL ÉCHANGE

Page 76

78 Rinnai Corporation EX17C / EX22C Manual Schéma de câblage Si des fils d’origine livrés avec l’appareil ont besoin d’être

Page 77

Rinnai Corporation EX17C / EX22C Manual 79 MARQUAGE NOM DE PIÈCE MS INRERRUPTEUR D’ALIMENTATION R.TH THERMISTANCE TF FUSIBLE THERMIQUE F F

Page 78

8 Rinnai Corporation EX17C / EX22C Manual Operating the Heater Manually Setting the Clock 1. Press the “Set

Page 79

80 Rinnai Corporation EX17C / EX22C Manual Service à la clientèle Informations de garantie Garantie limitée

Page 80 - Service à la clientèle

Rinnai Corporation EX17C / EX22C Manual 81 Garantie limitée (Suite) Le remplacement du produit ne peut être autorisé que par

Page 81

82 Rinnai Corporation EX17C / EX22C Manual Notes

Page 82

Rinnai Corporation EX17C / EX22C Manual 83 Notes

Page 83

Rinnai’s other fine productsFor information on Rinnai’s products contactRinnai America Corporation103 International DrivePeachtree City, GA 30269TOL

Page 84 - Rinnai’s other fine products

Rinnai Corporation EX17C / EX22C Manual 9 Override Function This function is used only when the heater is in Timer operati

Related models: EX17C (RHFE-434FTA)

Comments to this Manuals

No comments